56/200
2.114.
FRAME RESPONSE [VXX:FDYI0]
Hexadecimal
02h
41h
44h
5Ah
5Ah
3Bh
56h
58h
58h
3Ah
Character
A
D
Z
Z
;
V
X
X
:
Hexadecimal
46h
44h
59h
49h
30h
3Dh
2Bh
*1
*3
*5
Character
F
D
Y
I
0
=
+
*2
*4
*6
Hexadecimal
*7
*9
03h
Character
*8
*10
Parameters(*1,*2,*3,*4,*5,*6,*7,*8,*9,*10)
NORMAL
FAST
FIXED
Hexadecimal
30h 30h 30h 30h
30h
30h
30h
30h
30h
31h
30h 30h 30h 30h
35h
Character
0
0
0
0
0
0
0
0
0
1
0
0
0
0
5
Response (Callback)
In the period when the command can be accepted
Hexadecimal
02h
56h
58h
58h
3Ah
46h
44h
59h
49h
30h
Character
V
X
X
:
F
D
Y
I
0
Hexadecimal
3Dh
2Bh
*1
*3
*5
*7
*9
03h
Character
=
+
*2
*4
*6
*8
*10
Acceptability
SECURITY
STANDBY
ECO
STANDBY
NO
SIGNAL
SHUTTER
FREEZE
TEST
PATTERN
REMOTE2
P IN P
LENS
HOME
×
×
×
×
○
×
○
○
×
×
2.115.
RASTER POSITION
–
HORIZONTAL [VRH]
Hexadecimal
02h
41h
44h
5Ah
5Ah
3Bh
56h
52h
48h
3Ah
Character
A
D
Z
Z
;
V
R
H
:
Hexadecimal
*1
*3
*5
*7
03h
Character
*2
*4
*6
*8
Parameters(*1,*2,*3,*4,*5,*6,*7,*8)
-2048
-2047
Hexadecimal
32h
39h
35h
32h
32h
39h
35h
33h
Character
2
9
5
2
2
9
5
3
+2046
+2047
Hexadecimal
37h
30h
34h
36h
37h
30h
34h
37h
Character
7
0
4
6
7
0
4
7
Response (Callback)
In the period when the command can be accepted
Hexadecimal
02h
56h
52h
48h
3Ah
*1
*3
*5
03h
Character
V
R
H
:
*2
*4
*6
Acceptability
SECURITY
STANDBY
ECO
STANDBY
NO
SIGNAL
SHUTTER
FREEZE
TEST
PATTERN
REMOTE2
P IN P
LENS
HOME
×
×
×
×
○
×
○
○
○
×
Note:
・From the input signal and aspect, zoom setting conditions, the maximum value will change.
2.116.
RASTER POSITION
–
VERTICAL [VRV]
Hexadecimal
02h
41h
44h
5Ah
5Ah
3Bh
56h
52h
56h
3Ah
Character
A
D
Z
Z
;
V
R
V
:
Hexadecimal
*1
*3
*5
*7
03h
Character
*2
*4
*6
*8
Parameters(*1,*2,*3,*4,*5,*6,*7,*8)
-2048
-2047
Hexadecimal
32h
39h
35h
32h
32h
39h
35h
33h
Character
2
9
5
2
2
9
5
3
+2046
+2047
Hexadecimal
37h
30h
34h
36h
37h
30h
34h
37h
Character
7
0
4
6
7
0
4
7
Response (Callback)
In the period when the command can be accepted
Hexadecimal
02h
56h
52h
56h
3Ah
*1
*3
*5
03h
Character
V
R
V
:
*2
*4
*6
Acceptability
SECURITY
STANDBY
ECO
STANDBY
NO
SIGNAL
SHUTTER
FREEZE
TEST
PATTERN
REMOTE2
P IN P
LENS
HOME
×
×
×
×
○
×
○
○
○
×
Note:
・From the input signal and aspect, zoom setting conditions, the maximum value will change.