18/200
2.5.
SHUTTER [OSH]
Hexadecimal
02h
41h
44h
5Ah
5Ah
3Bh
4Fh
53h
48h
3Ah
*1
03h
Character
A
D
Z
Z
;
O
S
H
:
*2
Parameters(*1,*2)
SHUTTER OFF
SHUTTER ON
Hexadecimal
30h
31h
Character
0
1
Response (Callback)
In the period when the command can be accepted
Hexadecimal
02h
4Fh
53h
48h
3Ah
*1
03h
Character
O
S
H
:
*2
Acceptability
SECURITY
STANDBY
ECO
STANDBY
NO SIGNAL
SHUTTER
FREEZE
TEST
PATTERN
REMOTE2
P IN P
LENS
HOME
○
○
×
○
○
○
○
△
○
×
Note:
・REMOTE2 is given to priority. In the case of a different command from a setup of REMOTE2, ER401 is returned.
2.6.
INPUT SELECT [IIS]
Hexadecimal
02h
41h
44h
5Ah
5Ah
3Bh
49h
49h
53h
3Ah
Character
A
D
Z
Z
;
I
I
S
:
Hexadecimal
*1
*3
*5
03h
Character
*2
*4
*6
Parameters(*1,*2,*3,*4,*5,*6)
RGB1
RGB2
DIGITAL LINK
Hexadecimal
52h
47h
31h
52h
47h
32h
44h
4Ch
31h
Character
R
G
1
R
G
2
D
L
1
DVI
HDMI
SDI
Hexadecimal
44h
56h
49h
48h
44h
31h
53h
44h
31h
Character
D
V
I
H
D
1
S
D
1
Response (Callback)
In the period when the command can be accepted
Hexadecimal
02h
49h
49h
53h
3Ah
*1
*3
*5
03h
Character
I
I
S
:
*2
*4
*6
Acceptability
SECURITY
STANDBY
ECO
STANDBY
NO SIGNAL
SHUTTER
FREEZE
TEST
PATTERN
REMOTE2
P IN P
LENS
HOME
×
○
×
○
○
○
○
△
○
×
Note:
・REMOTE2 is given to priority. Calls back ER402 if the input select of REMOTE2 is available.
・If PT-RZ670 parameters SD1is available. In other case, ER401 is returned.
2.7.
INPUT SELECT (DIGITAL LINK) [IIS]
Hexadecimal
02h
41h
44h
5Ah
5Ah
3Bh
49h
49h
53h
3Ah
Character
A
D
Z
Z
;
I
I
S
:
Hexadecimal
44h
4Ch
31h
3Ah
*1
*3
*5
03h
Character
D
L
1
:
*2
*4
*6
Parameters
(*1,*2,*3,*4,*5,*6)
HDMI1
HDMI2
COMPUTER1
Hexadecimal
48h
44h
31h
48h
44h
32h
50h
43h
31h
Character
H
D
1
H
D
2
P
C
1
COMPUTER2
S-VIDEO
VIDEO
Hexadecimal
50h
43h
32h
53h
56h
44h
56h
49h
44h
Character
P
C
2
S
V
D
V
I
D
Response (Callback)
In the period when the command can be accepted
Hexadecimal
02h
49h
49h
53h
3Ah
44h
4Ch
31h
3Ah
Character
I
I
S
:
D
L
1
:
Hexadecimal
*1
*3
*5
03h
Character
*2
*4
*6
Acceptability
SECURITY
STANDBY
ECO
STANDBY
NO SIGNAL
SHUTTER
FREEZE
TEST
PATTERN
REMOTE2
P IN P
LENS
HOME
×
○
×
○
○
○
○
△
○
×
Note:
・
REMOTE2 is given to priority. Calls back Er402 if the input select of REMOTE2 is available.
・It is effective only when the digital interface box is connected.