68
Using PJLink™ protocol
The projector’s network functions conform to PJLink™ Class 1 standards, enabling the following operations from a computer
using the PJLink™ protocol.
• Setting the projector
• Querying the projector status
The following commands are used to control the projector with the PJLink™ protocol.
Applicable commands
Command
Control details
Notes
POWR
Power control
Parameters
0 = Standby
1 = On
POWR ?
Power status query
Parameters
0 = Standby 1 = On
2 = Cooling down 3 = Warming up
INPT
Input switching
Parameters
11 = COMPUTER1 12=COMPUTER2
21 = VIDEO 22=S-VIDEO
23 = COMPONENT
51 = NETWORK
INPT ?
Input switching query
AVMT
Shutter control
Parameters
30 = Shutter mode off (video mute cancelled)
31 = Shutter mode on (video mute)
AVMT ?
Shutter status query
ERST?
Error status query
Parameters
1st byte : Indicates fan errors; a number from 0 to 2
2nd byte : Indicates lamp errors; a number from 0 to 2
3rd byte : Indicates temperature errors; a number from 0 to 2
4th byte : Fixed at 0
5th byte : Indicates filter errors; a number from 0 to 2
6th byte : Indicates other errors; a number from 0 to 2
Numbers from 0 to 2 indicate the following
0 = No error detected
1 = Warning
2 = Error
LAMP ?
Lamp status query
Parameters
1st number (1–5 digits): Cumulative hours of lamp use
2nd number: 0 = lamp off; 1 = lamp lit
INST ?
Input switching list query
The following values are returned in this parameter
“11 12 21 22 23 51”
NAME ?
Projector name query
Returns the name set in “HOSTNAME
※
,” in “NETWORK”
※
The “HOSTNAME” is the projector name set in the projector itself.
INF1 ?
Manufacturer name query
Returns “Panasonic”
INF2 ?
Model name query
Returns “F200NT”/“FW100NT”
INFO ?
Query for other information
Returns the version number or similar identification
CLSS ?
Class information query
Returns “1”
PJLink™ security authentication
The password used for PJLink™ is the same as the password set for WebBrowser control.
When using these commands without authentication, leave the WebBrowser control password unspecified.
PJLink™ is a pending trademark in Japan, the United States and other countries and regions. For details on PJLink™
specifications, refer to the Japan Business Machine and Information System Industries Association website.
The URL is http://pjlink.jbmia.or.jp/english/
The system locks for several minutes if an incorrect password is entered three times in succession.