[NETWORK] menu
ENGLISH - 77
Settings
■
Error information page
When [Error (Detail)] is displayed on the [Projector status] screen, click it to display the error details.
z
The projector may go into the standby status to protect the projector depending on the contents of the
error.
[OK]: Normal operation
[FAILED]: Occurrence of trouble
z
Description of problem occurrence [FAILED]:
Parameter
Description
[MAIN CPU BUS]
There is a problem with the microcomputer circuitry. Consult your
dealer.
[FAN]
There is a problem with the fan or the fan drive circuit. Consult your
dealer.
[INTAKE AIR TEMPERATURE]
The air intake temperature is too high. It may be used in an operating
environment where the temperature is high, such as near a heating
appliance.
[OPTICS MODULE TEMPERATURE]
The temperature inside the projector is high. It may be used in an
operating environment where the temperature is high, such as near a
heating appliance.
[AROUND LAMP TEMPERATURE]
The temperature around the lamp is high. The air exhaust port may
be blocked.
[LAMP1 REMAIN TIME]
The usage time of the lamp has exceeded the specified time, and it is
time to replace the lamp.
[LAMP2 REMAIN TIME]
[LAMP1 STATUS]
The lamp has failed to turn on. Wait a while until the luminous lamp
cools off, and then turn on the power.
[LAMP2 STATUS]
[SHUTTER]
There is a problem with the shutter circuitry. Consult your dealer.
[INTAKE AIR TEMP.SENSOR]
There is a problem with the sensor used to detect intake air
temperature. Consult your dealer.
[OPTICS MODULE TEMP.SENSOR]
There is a problem with the sensor used to detect temperature inside
the projector. Consult your dealer.
[AROUND LAMP TEMP. SENSOR]
There is a problem with the sensor used to detect exhaust air
temperature. Consult your dealer.
[BATTERY]
The battery replacement is required. Consult your dealer.
[AIRFLOW SENSOR]
There is a problem with the air volume sensor. Consult your dealer.
[COLOR WHEEL]
There is a problem with the color wheel or the color wheel drive
circuit. Consult your dealer.
[COVER OPEN]
The attachment of the lamp unit cover is incomplete. Check the lamp
unit cover. (
page 92)
[FILTER UNIT]
The air filter unit is not attached. Check the air filter unit. (
page 90)
[AIR FILTER]
There are too much dust accumulated in the air filter unit.
Set the <MAIN POWER> switch (
page 35) to <OFF>, and clean the
air filter (
page 89).