background image

If you find any problem, please take the following steps to check.

 LED

The POWER LED (Power) is not lit.

 

Is the power plug connected?

 

Check that the power plug is firmly connected, so the connection is not loose at

The SD CARD LED is not lit.

 

Is the SD card installed?

 

Check that the SD card

the power port.

is firmly inserted.

If the STATUS LEDs are blinking orange

If the STATUS LEDs are blinking green

Is the Ethernet Switch being used at a temperature between 0 and 50

?

Check whether the loops have occurred, since this is an indication that one or more 
ports are within 3 days after loop resolution.

17

Troubleshooting

Use the Ethernet Switch in its operating temperature range.
If used at a temperature out of the operating temperature range, STATUS LED 
blinks in orange and indicates abnormality.

Communication Failure

   Is the UTP/fiber cable connected to the correct port?

  Are the SFP modules complied with the same standard each other?

 Is the fiber cable correct the fiber mode (single or multi)?

Are the communication speed and mode settings correct?

If the communication mode signal cannot be properly obtained, the Ethernet Switch
operates in half-duplex mode. Check the auto negotiation setting again.
Do not fix the speed/duplex mode of the connected terminal to full-duplex mode.



Attempt to disable “EEE conforming to IEEE802.3az (LPI)” function at target port.

 


Are the equipment linked up?
If Embedded power-saving mode is set to "Full", change it to "Half" or "Disabled".

Is the device whose communication mode fixed to half-duplex mode or full-duplex 
mode connected to ports 17 to 20?
Ports 17 to 20 do not link up with devices in fixed mode. 
Connect the device to ports 1 to 16 or enable auto negotiation of the device you 
want to connect.

   Is the usage rate of the network to which this Ethernet Switch is connected excessively   

     

high?
Try separating this 

Ethernet Switch from the network.

Summary of Contents for PN26161K-ID

Page 1: ...ot covered by the warranty C0219 10222 ZEQUO 2310 Model No Installation Guide Printed in Japan PN26161K TH PN26161K MY PN26161K ID PN26161K SG 2 12 7 Higashi Shimbashi Minato ku Tokyo Japan 105 0021 Panasonic Electric Works Networks Co Ltd Panasonic Electric Works Networks Co Ltd 2022 The instruction manuals CLI Version and Web Version latest firmware and SDN application ZEQUO assist Plus can be d...

Page 2: ...ne 1 1 Features 1 2 Specifications 1 3 Accessories 1 4 Basic operation 2 Part Names and Functions 3 Installation and Configuration 3 6 7 7 8 9 10 11 13 3 2 Installing on level shelves 14 3 1 Grounding Cable Connection 13 3 3 Mounting to rack 3 4 Configuration of IP address Basic Troubleshooting 14 15 17 ...

Page 3: ...ings or boards Do not use the Ethernet Switch in very dusty areas such as on floors underneath floors the backside of ceilings or boards Deviation could lead to fire electrical shock and or equipment failure It is recommended that the Ethernet Switch be operated in environments such as the inside of racks where it is difficult for dust to be generated Do not store or use the Ethernet Switch in pla...

Page 4: ...hands from being damaged by twisted pair port SFP extension slot console port SD card slot or power cord hook block CAUTION Do not connect any other devices except for 10BASE T 100BASE TX 1000BASE T devices to the twisted pair ports Deviation could lead to equipment failure Do not insert any other modules except for our optional SFP module PN54022 PN54024 to the SFP extension slots Check out our w...

Page 5: ... means to ensure safety and reliability This Ethernet Switch is not designed or manufactured with the intention that it be used for applications in use with railways aviation and medical care etc where the influence rate due to communication failures is extremely high in regard to systems that directly affect systems and human lives which require extremely high reliability It is recommended that t...

Page 6: ...illed liquid water Dusty Possible static charge such as carpet Under direct sunlight Possible condensation High low temperature exceeding the specifications environment Strong vibration and or strong shock Please use this Ethernet Switch in place where ambient temperature is from 0 to 50 C Failure to meet the above conditions may result in fire electric shock breakdown Select the appropriate cable...

Page 7: ... volumes when not linked up Factory default deactivated Due to the loop detection shutoff function a port where loop has occurred can be automatically shut off to prevent loop failures When a port is shut off and recovered automatically SNMP trap can be sent to notify the incident to the administrator Moreover the port with a loop can be identified by loop notification on the LEDs on the main unit...

Page 8: ...P Management DHCP relay agent Console TELNET SSH WEB SNMPv1 v2c v3 ZEQUO assist Plus Power supply AC 100 240 V 50 60 Hz 0 6 A 8 Product Outline 1 Tag VLAN MAC base VLAN Subnet base VLAN Protocol base VLAN Dynamic VLAN Guest VLAN Link aggregation STATIC LACP SPAN RSPAN Port monitoring IEEE 802 3 Transmission system Transmission system RS 232C ITU TS V 24 10BASE T IEEE 802 3u 100BASE TX IEEE 802 3ab...

Page 9: ...llowing power cords are supplied as per the intended nation of delivery The XXs are identical to the intended nation of delivery codes Please contact our distributor if any of the contents are insufficient Quantity Optional accessories PN54022 XX 1000BASE SX SFP Module i PN54024 XX 1000BASE LX SFP Module i Locale Thailand 250 VAC 6 A TIS166 2549 Indonesia 250 VAC 10 A 250 VAC 10 A 250 VAC 5 A CEE7...

Page 10: ... LED lights up orange and the hardware s self diagnostic is implemented On completion of self diagnosis STATUS LED light in green and the Ethernet Switch starts operation as a Ethernet Switch When this Ethernet Switch successfully communicates with a terminal connected to a port the Port LED lights up When the terminal is not operating normally for example when power is not supplied to the termina...

Page 11: ...ed the port is automatically switched to SFP extension mode SFP port supports only the full duplex communication Console port Connect a VT100 compatible terminal etc with this port to configure or manage this Ethernet Switch Transmission mode RS 232C Transmission speed 9 600 bps Stop bit 1 bit Flow control None Emulation mode VT100 Data length 8 bits Parity control None Transmission connector RJ45...

Page 12: ...ting and receiving data at 10 100 1000 Mbps Shutting off due to loop detection and shutoff functions storm controls BPDU guard Orange Light Orange Blink Off No devices are connected Port LED SFP Port 17 20 Green Light Link is established at 1000 Mbps Green Blink Transmitting and receiving data at 1000 Mbps Shutting off due to loop detection and shutoff functions storm controls BPDU guard Orange Li...

Page 13: ...n 18 AWG and the length is 50 cm 3 The ground installed screw shall comply with 3 5mm minimum in nominal thread diameter and engage at least two complete threads into metal chassis with appropriate fixing hardware like washer 4 The grounding cable shall not be removed during normal operation servicing or maintenance 5 Installation steps Step 1 Ensure the detachable power supply cord removed Step 2...

Page 14: ...t Switch firmly to the rack using the supplied 4 screws for 19 inch rack or screws furnished at the rack The main unit can be placed 20 mm back on the rack by changing the bracket fixing position 20 mm 3 2 Installing on level shelves 1 Apply the supplied rubber feet onto the bottom surface of the unit 2 Install in a level area Caution Do not stack and use Set up with a clearance of 20 mm or more B...

Page 15: ...ed Screen 2 4 Enter the IP address and subnet mask using the following command Screen 3 enable configure config interface vlan1 config if ip address 192 168 1 254 255 255 255 0 5 Enter the following command to save the setting Since the following screen is displayed enter Y and the settings will be saved Screen 4 config if exit config exit copy running config startup config 6 From terminals connec...

Page 16: ...he PDF version of the Operating Instructions on Panasonic s website Detailed configuration and management methods using the CLI Configuration and management method from ZEQUO assist Plus 2 n e e r c S 4 n e e r c S 3 n e e r c S 16 Installation and Configuration 3 ...

Page 17: ...le connected to the correct port Are the SFP modules complied with the same standard each other Is the fiber cable correct the fiber mode single or multi Are the communication speed and mode settings correct If the communication mode signal cannot be properly obtained the Ethernet Switch operates in half duplex mode Check the auto negotiation setting again Do not fix the speed duplex mode of the c...

Page 18: ...d blocking functions After the port controlled loop connections are resolved release the port blocking from the settings screen as to whether the standby time will be longer than the recovery time until the auto recovery of the loop detection and blocking 18 Troubleshooting Please refer to the instruction manual on the ZEQUO assist Plus on Panasonic s website in regard to settings and management m...

Reviews: