14
EN
the drawings below.
Connection to solar panels and central heating hot-water system
Legend:
WARNING:
If the temperature of the additional heating source drops and the
circulation of water through the heat transmitter is enabled the heat can
uncontrollably be taken from the water tank. When attaching the appliance to other
heating sources, the additional source temperature must be properly regulated.
WARNING:
In case of connecting solar panels as an external source of heat, the
operation of the aggregate of the heating pump must be turned off. A combination of
those two sources can lead to overheating of the domestic water, resulting in
excessively high pressures.
Connection to solar panels
Connection to the central
heating hot-water system
4
8
11 13
3
9
T
5
T
8
12
7
10
6
2
1
1
7 14
15
9
7
T
3
12
2
5
12
8
7
15
14
11
13
1
1
T
4
9
7
T
3
12
2
1
T
1
6
7
10
5
4
3
2
T
9
8
5
4
T
12
8
15
7 14 11 13
1 - Water heater
2 - Central heating hot-water system
3 - Solar panel
4 - Differential thermostat with sensors
(T1, T2, T3, T4)
5 - Bypass pump
6 - Expansion tank
7 - Non-return valve
8 - Safety valve
9 - Air relief valve
10 - Fill/drain valve
11 - Reduction valve
12 - Drain valve
13 - Stop valve
14 - Test unit
15 - Funnel outlet to the drain
Summary of Contents for PAW-DHWM300ZC
Page 16: ...16 EN ...
Page 32: ...32 DE ...
Page 64: ...64 ES cercano ...
Page 79: ...79 DA ...
Page 94: ...94 NO ...
Page 109: ...109 SV ...
Page 124: ...124 HR BIH ...
Page 139: ...139 CS ...
Page 154: ...154 HU ...
Page 171: ...171 ...