Diagnosis
display
Abnormality
or
protection
control
LED 6 LED 5 LED 4 LED 3 LED 2 LED 1
Abnormality
judgement
Protection
operation
Problem Check
location
H37 Outdoor
liquid
pipe
temperature
sensor
abnormality
O O O
Continuous
for 5s
Cooling
protection
operation only
Outdoor liquid pipe
temperature sensor
open or short circuit
Outdoor liquid
pipe temperature
sensor lead wire
and connector
H64 Outdoor
high
pressure
sensor
abnormality
O O
Continuous
for 1 minutes
―
High pressure sensor
open circuit during
compressor stop
High pressure
sensor
Lead wire and
connector
H97 Outdoor
fan
motor
mechanism
lock
O O O
2
times
happen within
30 minutes
―
Outdoor fan motor
lock or feedback
abnormal
Outdoor fan
motor lead wire
and connector
Fan motor lock or
block
H98 Indoor
high
pressure
protection
O O O
―
―
Indoor high pressure
protection (Heating)
Check indoor
heat exchanger
Air filter dirty
Air circulation
short circuit
H99 Indoor
operating unit
freeze
protection
O O O
―
―
Indoor
freeze
protection (Cooling)
Check indoor
heat exchanger
Air filter dirty
Air circulation
short circuit
F11 4-way
valve
switching
abnormality
O O O O
4
times
happen within
30 minutes
―
4-way
valve
switching abnormal
4-way valve
Lead wire and
connector.
F17 Indoor
standby
units freezing
abnormality
O
3
times
happen within
40 minutes
―
Wrong
wiring
and
connecting pipe,
expansion valve
leakage, indoor heat
exchanger sensor
open circuit
Check indoor/
outdoor
connection wire
and pipe
Indoor heat
exchanger
sensor lead wire
and connector
Expansion valve
lead wire and
connector.
F90 Power
factor
correction
(PFC) circuit
protection
O O
4
times
happen within
10 minutes
―
Power
factor
correction circuit
abnormal
Outdoor PCB
faulty
F91 Refrigeration
cycle
abnormality
O O
2
times
happen within
20 minutes
―
Refrigeration
cycle
abnormal
Insufficient
refrigerant or
valve close
F93 Compressor
abnormal
revolution
O O O
4
times
happen within
20 minutes
―
Compressor
abnormal revolution
Power transistor
module faulty or
compressor lock
F94 Compressor
discharge
pressure
overshoot
protection
O O
4
times
happen within
30 minutes
―
Compressor
discharge pressure
overshoot
Check
refrigeration
system
F95 Outdoor
cooling high
pressure
protection
O O O
4
times
happen within
20 minutes
―
Cooling
high
pressure protection
Check
refrigeration
system
Outdoor air
circuit