PAN9420 Quick Start Guide
Quick Start Guide Rev. 1.0
Page 16
Default configuration for UART0 and UART1:
Baud rate:
115200
Data bits:
8
Parity bit:
none
Stop bits:
1
UART0 does not utilize any flow control.
UART1 utilizes HW flow control (RTS/CTS). To achieve maximal throughput,
flow control for UART1 is required.
If successfully connected, try to send the command
get system firmware
using your
Terminal Program of choice, to request the firmware version of the module.
A command MUST BE followed by CR (Carriage Return) and LF (Line Feed)
as described in the communication specification. You can set your terminal to
issue them automatically.
You might also need to set the terminal’s echo.
If you did not use HTerm before, please note:
If you are new to HTerm, please do not use the ASend button.
To invoke a command in Hterm
–
Type it in
Press
[Enter]
on your keyboard
Figure 8: Invoking a command in HTerm