Panasonic PalmLink KX-TR320CF Operating Instructions Manual Download Page 5

KX-TR325 allows you to scramble your calls so that others will not
understand your conversation. This is only possible with KX-TR325.
The factory preset is OFF.

1

Press 

(MENU)

six times.

SCRAMBLE ” and the current setting will

flash on the display.

2

Press 

(›)

or 

(‹)

to turn on/off the

scrambling function.

3

When finished, press 

(TALK) 

or wait for

10 seconds.

When set to ON, “

SCRAMBLE ” will

remain on the display.

The unit can be programmed to turn itself off after a certain period of
no operation. This is useful to save the battery life. You can select
the time period for the auto power off mode. The factory preset is “2”
(2 hours).

1

Press 

(MENU)

five times (seven times 

if your model is a KX-TR325).

The current setting will flash on the
display.

2

Press 

(›)

or 

(‹)

repeatedly until the

desired setting (0–3) is displayed.

1: 1 hour

2: 2 hours

3: 3 hours 

0: OFF

3

When finished, press 

(TALK) 

or wait for 10 seconds.

The auto power off function can be used whether the Key Lock
function is active or not (5-A). 

5-B Auto Power OFF

5-A Key Lock

Key lock allows you to lock some buttons (

(POWER)

(MENU)

(›)

,

(‹)

and 

(SCAN)

) to prevent accidentally changing any radio

settings.

1

Press and hold 

(LOCK)

until “ ” is

displayed.

2

To turn the key lock function OFF,
press and hold 

(LOCK)

until “ ”

disappears.

While the Key Lock function is ON, the following features
can still be used.

Sending/Receiving messages

Sending/Receiving call tones

Monitor

Private talk

5

Special Features

Section 5

5-C Scrambling 

(KX-TR325 only)

4

Channel Scan

Section 4

4-A Finding a Busy Channel

Channel scan allows you to monitor 14 channels and a selected
group code. When the unit detects channel activity on your selected
code, it stops scanning and locks in on the busy channel. You can
listen and talk back (within 5 seconds of the end of a transmission)
on the displayed channel without having to change your settings.

1

Press 

(SCAN)

.

SCAN ” will flash on the display.

Channel scan starts and monitors the channels from the
current channel in the order below. 
1

-.

2

-.

3

- - - - - - - .

14

^_______n

2

The unit stops scanning when it finds a busy channel, and
you will hear a message.

The TALK/BUSY indicator lights green.

If you want to scan other busy channels, press 

(‹)

to

scroll up or 

(›)

to scroll down.

Channel scan starts again.

If no message is received or there is no key operation for about
5 seconds, channel scan starts again.

3

To end the channel scan, press 

(SCAN)

.

The unit will return to the standby mode with the preset channel
and group code.

To transmit during channel scan

1

Follow steps 1 and 2 of the channel scan procedure
above.

2

When the unit finds the desired busy channel and stops
scanning, press 

(TALK)

within 5 seconds (or during the

message).

3

To transmit, press and hold 

(TALK)

and talk into the

microphone. 
To receive, release 

(TALK)

.

After transmission, the unit will return to the standby mode
showing the current channel and group code.

If you want to scan privately, open the flip before pressing 

(SCAN)

To communicate in channel scan mode, your unit must be set to
the same group code as the other user(s) in your group. If your
unit is set to a different code, the channel scan function will not
detect channel activity in your group.

To scan for radios without a group code, set your group code to
“0” (OFF) before using the channel scan function.

PQQX12651XA-BM  00.7.27 9:55 AM  ページ 9

Summary of Contents for PalmLink KX-TR320CF

Page 1: ...LL Button 3 D SCAN Button 4 A POWER Button 1 F Display 1 B DC IN 4 5 V Jack 6 B TALK BUSY Indicator 3 A 3 B Microphone 3 B MONITOR Button 3 A The flip is open 3 C The scrambling function is ON KX TR325 only 5 C The unit is in the VOX mode 6 A The key lock function is ON 5 A The unit is in the vibratory call mode KX TR325 only 3 E The display shows the battery strength 1 C The volume is set to leve...

Page 2: ...tion number for details Press or for the desired settings When finished press TALK or wait for 10 seconds You can exit the programming mode any time by pressing TALK or waiting for 10 seconds 1 Pull down the hook and remove the cover 2 Install or replace the batteries using the correct polarity r s 1 2 3 Close the cover 1 2 3 Make sure that the unit is powered OFF before replacing the batteries Ba...

Page 3: ...es 1 Check the current channel activity 3 A Do not talk if someone is already on the channel 2 Press and hold TALK to transmit and talk into the microphone The TALK BUSY indicator lights red 3 To receive release TALK The TALK BUSY indicator lights green Repeat steps 2 and 3 to continue communication To maximize readability of your transmitted signal pause a few seconds after pressing TALK hold the...

Page 4: ... call tones will sound continuously if you press and hold CALL If you want to send the call tones privately open the flip before pressing CALL To change the call tones The factory preset is 1 1 Press MENU four times CALL and the current setting will flash on the display 2 Press or repeatedly until the desired setting 1 5 is displayed Each time you press the button the selected call tones will soun...

Page 5: ...14 channels and a selected group code When the unit detects channel activity on your selected code it stops scanning and locks in on the busy channel You can listen and talk back within 5 seconds of the end of a transmission on the displayed channel without having to change your settings 1 Press SCAN SCAN will flash on the display Channel scan starts and monitors the channels from the current chan...

Page 6: ...aptor 6 B For Use with a Car Battery The unit has built in Voice Activated Transmission VOX capability Using a Headset Mic KX TRA10C with the unit you can activate the transmission with your voice The unit must be powered off before connection The unit enters the VOX mode when the unit is powered ON after the Headset Mic is connected to the unit VOX is displayed To switch to the PTT Push To Talk m...

Page 7: ...and 467 5625 to 467 7125 MHz and the power output level is up to 0 5 watts Do not use the unit in health care facilities if any regulations posted in the area instruct you not to do so Hospitals or health care facilities may be using equipment that could be sensitive to external RF radio frequency energy Routine care wipe the unit with a soft cloth Do not use benzine thinner or any abrasive powder...

Page 8: ...e after cold storage LIMITATIONS AND EXCLUSIONS This warranty does not apply to products purchased outside Canada or to any product which has been improperly installed subjected to usage for which the product was not designed misused or abused damaged during shipping or which has been altered or repaired in any way that affects the reliability or detracts from the performance nor does it cover any...

Reviews: