background image

11

LSQT0878

To Display the Approximate Remaining 
Tape Time

The remaining tape time can be displayed in the VCR display.

1 Select [TAPE SELECT] from the On Screen Display and 

select the corresponding video cassette tape length. 
See page 8.

2 Press [STATUS/ NAVI CHECK] 

(32)

 repeatedly until the 

Remaining Tape Time appears on the VCR display.

For certain cassettes, the remaining tape time may not be 
displayed correctly.

To reset the tape counter 

Press [RESET] 

(31)

 to reset the tape counter (elapsed time) 

to [0:00].
• The tape counter is automatically reset to [0:00] when a 

video cassette is inserted.

• The tape counter is reset to [0:00] when you operate the Jet 

Rewind function and the tape is rewound to the beginning.

Notes:

• When playing back a cassette recorded in the LP or EP 

mode, some pictures and sound distortion may occur. 
However, this is not a malfunction.

• The recording pause mode will be automatically cancelled 

after 5 minutes and return to the stop mode.

• The tape recorded in the EP mode on this VCR cannot be 

played back on the other VCR without EP mode function.

• On the other VCR (even with EP mode function), when you 

play back the tape recorded in the EP mode, the picture and 
the sound may be distorted. However, this is not a 
malfunction. 

Recording of Stereo or Bilingual 
Programmes

1 Recording is automatically made in the stereo or 

bilingual mode. This prevents errors in the selection of 
the dubbed or the original language.

2 During playback press [AUDIO] 

(22)

 to select the 

desired sound mode. (See page 7.)

The NICAM Broadcast System

The VCR is equipped with the NICAM sound system. NICAM 
is a 2 channel sound broadcast system to provide either a 
high quality stereo sound track or 2 independent MONO 
sound tracks, M1 and M2.
NICAM programmes are always accompanied by standard 
sound broadcasts and you can select the desired sound with 
[AUDIO] 

(22)

 during playback.

• The NICAM digital stereo sound can only be recorded on the 

Hi-Fi audio track.

• When NICAM programme is being received, the indicators 

are lit to inform you the type of broadcast. (See page 7.)

• To record the regular sound (ordinary normal sound) on the 

FM audio tracks when a NICAM programme is received, set 
[MONAURAL] to [ON]. (See page 9.)

• To hear stereo performance connect as shown on page 4 to 

a TV or Stereo Amplifier with left and right audio inputs.

Important Note for the NICAM System

When The VCR is switched on, the tuner will automatically 
switch to a NICAM broadcast, if NICAM is being transmitted.
At this time the NICAM signal is transmitted on stereo 
channels only, since the M1 and M2 formats are not yet 
available. Even if the sound track is MONO, the stereo 
indicator will appear.

To Record the Present Date and Time 
(OSD Recording) on the same screen as 
the picture

This function allows you to record the present date and time 
on the same screen as the picture being recorded.

Operations
1 Set [OSD REC] to [ON]. 

(See page 9.)

2 Press [REC] 

(15)

 ([REC/OTR] 

(39)

).

3 Press [STOP] 

(12)

 to stop 

recording.

Note:

• This function is also activated for OTR recording and Timer 

recording.

To Select the Recording Duration and 
Perform Timer Recording (OTR Recording)

OTR means One-Touch Recording and is called this way, 
because you can start recording and select the recording 
duration by repeatedly pressing a single button. This is very 
convenient, for example when you want to start recording 
immediately but need to go out or want to go to bed. 
After the selected recording duration has elapsed, recording 
stops and the VCR automatically switches off.

To Perform an OTR Recording:
1 Display the VCR picture on the TV.

2 Insert a video cassette with an intact erasure 

prevention tab.

3 Press [CH]

 

(20)

 to select the programme position on 

which the TV programme to be recorded will be 
broadcast.

4 Press [REC/OTR] 

(39)

 to start recording.

5 Press [REC/OTR] 

(39)

 repeatedly to select the desired 

recording duration.

• Every time you press this button, the recording duration 

indicated in the VCR display changes in the following 
order.

• For example, if you select [30], the VCR records a 

programme for 30 minutes.

Counter display (normal recording mode) 

#

 30 (min.) 

#

 

60 (min.) 

#

 90 (min.) 

#

 120 (min.) 

#

 180 (min.) 

#

 

240 (min.) 

#

 Counter display (normal recording mode)

To Stop the OTR Recording Before the End:

Press [STOP] 

(12)

.

Notes:

• The OTR function works during normal recording.
• When the tape reaches its end during OTR recording, the 

VCR will turn itself off.

SP

SP

REMAIN

2 0 : 1 5 . 5 4
1 6 . O C T . 2 0 0 5

LSQT0878.book  11 ページ  2005年3月18日 金曜日 午後6時59分

Summary of Contents for NV-HV62PX

Page 1: ...Setting the Clock of Your VCR 7 Settings Using the On Screen Display 7 Option Setting 8 Playback 9 Recording 10 Timer Recording 13 Search Functions 15 Before Requesting Service 17 Specifications 19 Before attempting to connect operate or adjust this product please read these instructions completely Contents Page Operating Instructions Model No NV HV62PX A LSQT0878 ...

Page 2: ...tromagnetic objects Touching internal parts of the VCR Water or some other liquid Lightning Disconnect the aerial plug from the VCR during lightning storms Anything heavy on the VCR Connecting or handling the equipment with wet hands Using a cell phone near the VCR because doing so may cause noise to adversely affect the picture and sound Do Wipe the VCR with a clean and dry cloth Install the VCR ...

Page 3: ...4 RF IN socket 45 AUDIO IN sockets AV 1 46 AUDIO OUT sockets 47 RF OUT socket TV Operation using the remote control You can use TV ON OFF 17 1 AV 2 2 VOLN 19 3 and TV CH 18 4 on the remote control for your TV operation See page 4 1 To switch the TV on from standby mode OFF or vice versa On some TVs it is only possible to switch the TV to standby mode OFF with this button but not on In this case tr...

Page 4: ...ompatible with the VCR Remote Control Connections This section shows you how to connect the VCR to an aerial TV etc When the VCR is turned on after unpacking and connecting the aerial cable and the mains lead Plug in Auto Tuning starts automatically Basic Connections The following connections are required to record and play back the video cassette through the TV Connection to a TV using the Audio ...

Page 5: ...el for the VCR Note Even if the RF output channel has been changed it is not necessary to perform Auto Tuning Storing TV Broadcasts in Your VCR The VCR is fitted with its own tuner just like a normal TV and can be preset to receive up to 99 TV broadcast stations Plug in Auto Tuning When the VCR is turned on after connecting the aerial cable and the mains lead Auto Tuning starts Auto tuning searche...

Page 6: ...station has not been tuned press 2 1 28 again Press MENU 9 and repeat steps 3 7 for each programme position you want to tune to a station 8 Press MENU 9 three times to exit the On Screen Display Direct Tuning Follow steps 1 to 4 of Manual Tuning Procedure 5 Press 43 28 to select SEARCH 6 Press Numeric 3 to enter the number of the desired programme position For other channels that require tuning re...

Page 7: ...set to PAL MESECAM or NTSC When you want to record or play back in black and white set to B W 4 Press MENU 9 twice to exit the On Screen Display To Make Various Indicators Appear On Screen Display At a press of STATUS NAVI CHECK 32 the following indications appear on the TV screen Set OSD to AUTO See page 9 The display is released automatically after 5 seconds 1 Audio Output Mode Indicators At eac...

Page 8: ...tem used to record NTSC signals Press 2 1 28 to select AUTO Allows NTSC 4 43 or 3 58 signals to be distinguished automatically If the tape has not recorded correctly select 4 43 or 3 58 4 43 When recording NTSC 4 43 signals 3 58 When recording NTSC 3 58 signals Some programmes on NTSC 3 58 system cannot be recorded correctly by selecting 3 58 NTSC PB SELECT To select the colour TV system of the TV...

Page 9: ... normal playback when the button is released For High speed Cue or Review Playback JET SEARCH During playback tap Fast Forward 27 or Rewind 10 twice For Still Playback During playback press PAUSE SLOW 29 To return to normal playback press PLAY 8 or PAUSE SLOW 29 For Slow Playback During playback keep PAUSE SLOW 29 pressed for 2 seconds or more To return to normal playback press PLAY 8 Fast forward...

Page 10: ...e inserted cassette can be played back by pressing PLAY 8 Auto Rewind When the tape reaches the end the VCR automatically rewinds it to the beginning This function does not work during timer recording OTR recording and fast forwarding Automatic Switching Off and Ejection When the VCR is switched off the inserted cassette can be ejected simply by pressing STOP EJECT 40 The VCR will eject the casset...

Page 11: ...ormal sound on the FM audio tracks when a NICAM programme is received set MONAURAL to ON See page 9 To hear stereo performance connect as shown on page 4 to a TV or Stereo Amplifier with left and right audio inputs Important Note for the NICAM System When The VCR is switched on the tuner will automatically switch to a NICAM broadcast if NICAM is being transmitted At this time the NICAM signal is t...

Page 12: ... than 5 minutes in step 3 or 6 the VCR automatically switches over to stop mode to protect the video heads To Delete all of a Cassette s Contents Tape Refresh Function You can delete a cassette contents the picture the sound and the Jet Navigator data all at once Operations 1 Be sure to set JET NAVIGATOR to ON when you want to delete all contents of a cassette that is recorded while setting JET NA...

Page 13: ...LETE message appears These messages will not appear if timer recording is started immediately after TIMER REC 14 is pressed To Suspend the Timer Recording Standby Mode When you want to use the VCR for playback normal recording or some other operation before the programmed timer recording perform you can temporarily suspend the timer recording standby mode by pressing the TIMER REC 14 so that the i...

Page 14: ...timer programmes which are recorded before appears 2 Press 43 28 to select the timer programme which you want to record on the next week 3 Press ENTER 26 The Timer Programme List screen appears 4 Press TIMER REC 14 to switch the VCR over to the timer recording standby mode To delete an I Timer Programme 1 Press I TIMER 23 then press 34 28 to select the timer programme which you want to delete 2 Pr...

Page 15: ...ory Notes The Jet Navigator list is stored in each cassette Up to 20 cassettes and 50 programmes can be registered Signals approximately 10 seconds before and after the current tape position are checked During this checking CHECKING JET NAVIGATOR DATA is displayed on the TV screen Checking cannot be performed properly where there are no signals such as at unrecorded portions of the tape In this ca...

Page 16: ...g starts When you press REC 15 on the remote control during recording Conditions for correct operation of the Index search function The VCR must be in the stop mode or in the playback mode Each programme recorded on the tape must be at least 5 minutes long Preparations Display the VCR picture on the TV Insert a recorded video cassette Operation 1 Press INDEX 13 that corresponds to the direction fr...

Page 17: ... that you use video cassettes other than type E300 The playback picture is distorted when record the tape in the EP mode using MESECAM system However this is not a malfunction We recommend PAL system for recording in the EP mode Recording will not operate correctly The symptom description is indicated in brackets The indication flashes whenever recording is attempted The erasure prevention tab on ...

Page 18: ...ING V LOCK 20 _ and simultaneously If the Still Picture shaking V Lock Adjustment If the still picture shakes perform the following operation During still playback keep TRACKING V LOCK 20 _ or pressed until the picture stops shaking Precautions With certain TV models and tapes it may not be possible to adjust the tracking If you play back a cassette that was recorded on another VCR the picture qua...

Page 19: ... Luminance FM azimuth recording Colour signal converted subcarrier phase shift recording Input Level VIDEO IN PHONO 1 0 Vp p 75 ohm terminated Output Level VIDEO OUT PHONO 1 0 Vp p 75 ohm terminated RF Modulate UHF Channel E21 E69 75 ohm AUDIO Input Level AUDIO IN PHONO j6 dBV more than 47 kohm Output Level AUDIO OUT PHONO j6 dBV less than 1 kohm Audio Track 1 track Normal mono only 2 channels Hi ...

Page 20: ...Matsushita Electric Industrial Co Ltd Web Site http www panasonic co jp global A LSQT0878 F0405Ah0 ...

Reviews: