PROCEDURES
FIP DISPLAY
Connect the Oscilloscope to:
*CH1....Video Out (TW3002).
*CH2....V.FREQ.(TW6002)
Press the "4" key on the remote controller.
(Confirm that TW6002 becomes high(5V)).
Adjust the Frequency response by pressing the
"2"(increase) and/or "8"(decrease) key on the
Remote Controller. (See Fig.E2)
Store the Adjusted value by pressing the "5" key
on the Remote Controller.
Release the Service mode by pressing the EJECT
and FF keys simultaneously in 6 times until the FIP
becomes normal indication.
Fig. E5
3.3.7. LOCATION OF TEST POINTS & CONTROLS
3.3.8. CIRCUIT BOARD LAYOUT
19
Summary of Contents for NV-FJ623EC
Page 22: ...10 2 CASING PARTS SECTION 22 ...
Page 23: ...10 3 PACKING PARTS SECTION 23 ...
Page 24: ...11 REPLACEMENT PARTS LIST 24 ...
Page 25: ...11 1 CHASSIS PARTS SECTION PARTS LIST 25 ...
Page 31: ...C1108 ECQB1H223JF3 P CAPACITOR 50V 0 022U 31 ...
Page 37: ...FL7301 VLF0633 FILTER J0HACK000008 37 ...
Page 39: ...L3006 VLQ0599J101 COIL 100UH G0C101JA0026 39 ...
Page 107: ......
Page 108: ......
Page 109: ......
Page 110: ......
Page 111: ......
Page 112: ......
Page 113: ......
Page 114: ......
Page 115: ......
Page 116: ......
Page 117: ......
Page 118: ......
Page 119: ......
Page 120: ......
Page 121: ......
Page 122: ......
Page 123: ......
Page 124: ......
Page 125: ......
Page 126: ......
Page 127: ......
Page 128: ......
Page 129: ......
Page 130: ......
Page 131: ......
Page 132: ......
Page 133: ......
Page 134: ......
Page 135: ......
Page 136: ......
Page 137: ......
Page 138: ......
Page 139: ......
Page 140: ......
Page 141: ......
Page 142: ......
Page 143: ......
Page 144: ......
Page 145: ......
Page 146: ......
Page 147: ......
Page 148: ......
Page 149: ......
Page 150: ......
Page 151: ......
Page 152: ......