http://cxema.ru
PROCEDURES
FIP DISPLAY
Release the Service mode by pressing the EJECT and
FF keys simultaneously in 6 times until the FIP
becomes normal indication.
Fig. E4
3.3.6. VIDEO FREQUENCY RESPONSE ADJUSTMENT
PROCEDURES
FIP DISPLAY
Input the Video sweep signal.
(See Fig.E1)
Press the FF and EJECT Keys
simultaneously for 3 seconds.
Press the FF and EJECT Keys
simultaneously twice.
Press the EJECT key for 3
seconds.
Press the CH UP and/or CH
DOWN key until "11" is displayed
on FIP.
Insert the Self-recorded tape and
playback it. (SP/LP/EP mode)
Connect the Oscilloscope to:
*CH1....Video Out (TW3002).
*CH2....V.FREQ.(TW6002)
Press the "4" key on the remote controller.
(Confirm that TW6002 becomes high(5V)).
Adjust the Frequency response by pressing the
"2"(increase) and/or "8"(decrease) key on the Remote
Controller. (See Fig.E2)
Store the Adjusted value by pressing the "5" key on
the Remote Controller.
Release the Service mode by pressing the EJECT and
FF keys simultaneously in 6 times until the FIP
becomes normal indication.
Fig. E5
3.3.7. LOCATION OF TEST POINTS & CONTROLS
Summary of Contents for NV-FJ621B
Page 18: ...http cxema ru 3 3 8 CIRCUIT BOARD LAYOUT ...
Page 59: ...http cxema ru 10 2 CASING PARTS SECTION ...
Page 60: ...http cxema ru 10 3 PACKING PARTS SECTION ...
Page 61: ...http cxema ru 11 REPLACEMENT PARTS LIST 11 1 CHASSIS PARTS SECTION PARTS LIST ...
Page 68: ...http cxema ru ...
Page 70: ...http cxema ru ...
Page 72: ...http cxema ru ...
Page 74: ...http cxema ru ...
Page 76: ...http cxema ru ...
Page 81: ...http cxema ru ...
Page 83: ...http cxema ru ...
Page 85: ...http cxema ru ...
Page 87: ...http cxema ru ...
Page 89: ...http cxema ru ...