- 6 -
4. DISPLAY SPECIFICATION
NR-CY54AG, NR-CY557G
PROCESS INSPECTION
DISPLAY
Quick Freezing
Freezer Control
ECONAVI
INVERTER
Freezer Control button
Quick Freezing button
IN-PROCESS INSPECTION
START
CONDITION
Operate the following controls within 3 sec., within 30 sec., after power-on
while PC and FC door are open.
QUICK FREEZING BUTTON
➝
FREEZER CONTROL BUTTON
➝
QUICK
FREEZING BUTTON
END
CONDITION
1
Hold down QUICK FREEZING BUTTON for over a second.
(Manual
defrost)
2
After 4 hours (Defrost start)
CONTENTS
FOR CONTROL
COMP : R 6 (62rps)
FC FAN : VF4 (Ultrahigh Speed)
HEATER : DEFROST HEATER OFF
LED : ECONAVI LED and FREEZER LED [ NORMAL ]
BRINKING (ON_1sec/OFF_1sec)
MANUAL DEFROST
Hold down QUICK FREEZING BUTTON for over a sec.
AUTOGNOSIS
During in-process inspection.
JUDGEMENT
Indicate AUTOGNOSIS in which case abnormal condition.
NOISE MODE
For 45 sec., of the start of IN-PROCESS INSPECTION
CONTENTS
COMP : R 7 (71rps)
INSPECTION OF TEMP.
For 30 min., of the start of IN-PROCESS INSPECTION
JUDGEMENT
Normal or abnormality is displayed according to the range of drop of FCC
ALL FREEZER LED LIGHTING..........GOOD
ALL FREEZER LED BRINKING..........BAD
INSPECTION OF
ILLUMINANCE SENSOR
During IN-PROCESS INSPECTION
JUDGEMENT
After 1 min., of the start of IN-PROCESS INSPECTION.
Abnormality is judged according to variation width of input voltage of
illuminance sensor.
ECONAVI LED EXTINCTION..........GOOD
ECONAVI LED LIGHTING...............BAD
NR-CY54AG_CY557G.indd 6
NR-CY54AG_CY557G.indd 6
6/27/2559 BE 4:44 PM
6/27/2559 BE 4:44 PM