10.3 ECONAVI operation doesn’t work
(PC/FC/IC cooling condition is normal)
1
Is the temperature control set to
{ 2 (Middle) } for FC?
2
Does LED indicate “ECONAVI Led” or
“Quick Freezing” or “Freezer Control”
LED lighting and blinking?
3
Does “Quick Freezing” function
operating?
4
Is the FC temperature -17°C or below?
5
Does “Freezer Control” LED turn on
MAX blink?
6
Press “Freezer” button 5 seconds.
7
It is normal (keep a wait and see)
• FC set to { 2 (Middle) }
• Some LED indicator is displayed on
the notice indicator area, ECONAVI will
not operate.
• The internal temperature is high,
ECONAVI will not operate.
• Quick Freezing is operating, ECONAVI
will not operate.
• Faulty operation panel PCB.
• Faulty control PCB.
• Faulty operation panel PCB.
White in service mode, shield the sensing part of ECONAVI sensor from the light.
Keep 1 minute without door opening and closing to turn on the { ECONAVI } lamp.
Precondition : The refrigerator compartment and freezer compartment are set to { 2 (Middle) }.
YES
NO
NO
YES
NO
Turn off setting
If it meets the above condition, ECONAVI operation begins and the lamp lights when the door opening and closing
is not done for 3 hours. (with some exceptions)
Test of ECONAVI operation. (Quickly con
fi
rms for turning on the { ECONAVI } lamp)
NO
YES
YES
YES
YES
Unlit (ECONAVI)