5
2 Specifications
Model
NR-B53V2, NR-BG53V2, NR-B53VW2, NR-BG53VW2
Destination
UK
Europe except UK
Rating volume capacity
Total gross volume
615L
Total net volume
530L
Net refrigerator volume
324L
Net freezer volume
206L
External dimensions
width/depth/height (mm)
W905 x D710 x H1860
Internal dimensions
PC: width/depth/height (mm)
W421 × D505 × H1664
FC: width/depth/height (mm)
W315 × D401 × H1642
Installation size
Side: 25mm or above
Back: 50mm or above
Top: 30mm or above
Power supply plug & cord
Volt/Freq
230-240V/50HZ
220-230V/50HZ
Interior lamp (LED)
Rating
7W
IEC protection against electric shock classes
Class 1
Class
SN-T
Sensor def.fc
DFC
B=3819K, R(10
C)=3.899K
Sensor def.pc
DPC
B=3819K, R(10
C)=3.899K
Sensor fc
FCC
B=3850K, R(-20
C)=18.9K
Sensor pc
PCC
B=3808K, R(0
C)=6.409K
Sensor sc
SCC
B=3808K±2%, R(3
C)=7.490K
Sensor ice
ICC
B=3754K, R(-20
C)=22.33K
sensor ATC
ATC
B=3435K, R(25
C)=10.0K
FC PIPE HEATER
389
/136.0-148.1W (230-240V)
355.9
/136.1-148.6W (220-230V)
FC DRAIN HEATER
3345
/15.8W (230V)
FC COIL BAC/FC ACCUME HEATER
3538
/15.0W (230V)
PC DRAIN HEATER
3100
/17.1W (230V)
PC BACK HEATER
6000
/8.8W (230V)
PC PLATE HEATER
9680
/5.5W (230V)
TANK HEATER
6000
/8.8W (230V)
DISPENSER HEATER/
DISPENSER T HEATER
6560
/8.0W (230V)
WATER SUPPLY HEATER
15452
/3.4W (230V)
LAMP HEATER
9160
/5.8W (230V)
ICE MAKER A'SSY
EAU37119712 (230-240V)
EAU37119711 (220-230V)
ICE SHUTTER
STAA125A01 (DC12V)
Compressor
Type
Full hermetic reciprocating system
Model
EFI120E13DGH-COEMS
Rotation speed
25/33/42/52/67/75 (r/s)
3 Way valve
Model
SDF 0.8 3/2-4.3
Rating
240V/50HZ/0.3W
Water valve
Model
RIV-23A-81/X-1871
Rating
240V/50HZ
Overload relay
Model
MM3-71CCY
Operating temperature
100±5
C
Return temperature
61±8
C
Operating current (A)
7.1A±7.5%
Fan motor(for Refrigerator compartment) Model/Rating
FBA11J14VXJ/DC 14V below 3.36W
Fan motor(for Freezer Compartment)
Model/Rating
FBA11J14VXJ/DC 14V below 3.36W
Fan motor(for Compressor Room)
Model/Rating
4715JL09WS29G51/DC 11.5V below 2.19W
SINGLE DAMPER
Model/Rating
NSBC000/DC12V, 300pps
Defrost heater
Rating/Voltage
195W (230V)-212W (240V)
190W (220V)-208W (230V)
Thermal fuse
Rating
250V/7A/73
C
250V/7A/94
C
Oil charge
S10/215±5ml
Summary of Contents for NR-B53V2
Page 7: ...7 3 General Introduction 3 1 Flow of Refrigerant ...
Page 8: ...8 4 Features 4 1 Features 4 1 1 Inverter Technology 4 1 2 Vacuum Insulation Panel ...
Page 9: ...9 4 1 3 Optimum Humidity Control 4 1 4 Powerful Cooling ...
Page 10: ...10 4 1 5 LED Tower Lighting 4 1 6 Refrigerator Cases with Different Setting ...
Page 11: ...11 4 1 7 Other Storage Solutions ...
Page 12: ...12 4 1 8 Wide and Spacious Freezer Compartment ...
Page 13: ...13 4 1 9 Drawer Compartments of Freezer Compartment 4 1 10 Humidity Control ...
Page 14: ...14 4 1 11 Selectable Temperature Control 4 1 12 Vitamin LED ...
Page 15: ...15 4 1 13 Hygiene Active 4 1 14 Multi Hygienic System ...
Page 16: ...16 4 2 Functions ...
Page 23: ...23 Set temperature ranges Set on shipment 4 C ...
Page 25: ...25 6 Location of Controls and Components 6 1 Display and Control Panel ...
Page 26: ...26 6 2 Ice Water Dispenser Part ...
Page 27: ...27 6 3 Components ...
Page 29: ...29 7 1 2 Removing the doors ...
Page 30: ...30 ...
Page 31: ...31 7 1 3 Connecting the refrigerator to the water supply ...
Page 32: ...32 ...
Page 33: ...33 7 1 4 Installing the water filter ...
Page 34: ...34 7 1 5 Installing the refrigerator ...
Page 35: ...35 7 2 Getting started 7 2 1 Setting the temperature ...
Page 36: ...36 7 2 2 Using the handy functions ...
Page 37: ...37 7 2 3 How to use the Ice Water dispenser ...
Page 39: ...39 9 Service Mode 9 1 Self Diagnosis Control 9 1 1 Self Diagnosis Mode ...
Page 44: ...44 9 7 Special Function Setting ...
Page 45: ...45 10 Troubleshooting Guide 10 1 FC and PC not cooling at all Compressor does not run ...
Page 46: ...46 10 2 PC is not cooling or poor cooling FC cooling condition is normal ...
Page 47: ...47 10 3 FC is poor cooling Compressor run ...
Page 48: ...48 10 4 No ice comes out No ice in the ice box ...
Page 51: ...51 10 6 Test of Ice Making Operation 10 7 Operation of Automatic Ice Making Mechanism ...
Page 67: ...67 12 3 Cleaning and Maintenance ...
Page 68: ...68 12 3 1 Changing the water purifying filter ...
Page 69: ...69 13 Dimensions 13 1 Outside ...
Page 70: ...70 13 2 Inside ...
Page 72: ...72 15 Exploded View and Replacement Parts List 15 1 Exploded View 1 ...
Page 74: ...74 15 3 Exploded View 2 ...
Page 76: ...76 15 5 Exploded View 3 ...
Page 78: ...78 15 7 Exploded View 4 ...
Page 80: ...80 15 9 Exploded View 5 NR B54X1 Bundled parts ...