---- 14 ----
B420M/MS/MW, B480M/MS/MW,
B570M/MS/MW/D/D-*9, B53D2,
B643M/MS/MW/D/D-*9, B703M/MS/MW,
C603D, C703M/MS/MW/D
DEFROST TIMER
STARTING RELAY AND OVERLOAD
PROTECTOR
Remove the screws (5 pcs) which fix the comp. cover.
Remove the comp. cover.
Remove the clamp and the cover.
Unscrew screw (2pcs.).
Pull the connector downwards to remove.
Pushing the r ibs (2por tions), pull the timer box
rightwards.
Remove defrost timer, A.T bimetal thermo.
To replace the defrost timer
Be sure to set the timer in coolimg operation.
Rotating direction of cam shaft is counter-clockwise.
Pull the starting relay leftwards to remove.
Pushing both ends of clips inwards, pull up the overload
protector.
To replace the overload protector
The overload protector should be in the clip.
Install the protector to touch the compressor.
Rib
Relay cover
driver
Starting relay
Overload protector
Push inward
Clip
Rib
Screw
Screw
Defrost
Timer
Screw
Ac cord
assy
Screw
Comp. Cover
(only Asia models)
Screw
Screw
Screw