40
b. Pull Bag Joint from storage part of depths of
upper side of FC.
Cut Cable Tie of Bag Joint, then take Bag Joint.
c. Remove the connector of Temperature Fuse A’ssy,
then replace new Temp Fuse A’ssy.
NOTES ON INSTALLATION
• Tighten Temp Fuse A’ssy by Cable Tie to pipe of Evapo-
rator.
• Tighten Bag Joint that is put in the connector of Temp
Fuse A’ssy with other connectors by Cable Tie as
before.
• Store Bag Joint to the place as before.
3. DEFROST HEATER A’SSY
a. Remove Defrost Heater A’ssy forward from right
and left side hooks that are fixation of Defrost
Heater A’ssy while pressing up hooks.
b. Remove Heater Cover of upper side of Defrost
Heater A’ssy.
c. Unhook 10 hooks, then remove the wires of
Defrost Heater A’ssy.
d. Pull Bag Joint from storage part of depths of
upper side of FC.
Cut Cable Tie of Bag Joint, then take Bag Joint.
e. Pull out two connectors of Radiant Heater A’ssy,
then replace new Defrost Heater A’ssy.
NOTES ON INSTALLATION
• Install Heater Cover in rubber cap securely.
• Arrange the lead wires, hook them to the wire hooks.
• Tighten Bag Joint that is put in the connector of Defrost
Heater A’ssy with other connectors by Cable Tie as
before.
• Store Bag Joint to the place as before.
NOTES ON INSTALLATION OF COVER COIL FC A’SSY
• Install Cover Coil FC A’ssy in upper side of depths of
FC, then fix it by three screws.
• It might be cause of getting frost, in case of imperfect
installation of Cover Coil FC A’ssy.
Summary of Contents for NR-B30FG1
Page 5: ...5 2 Specifications ...
Page 6: ...6 3 General Introduction 3 1 Flow of Refrigerant ...
Page 7: ...7 4 Features and Functions 4 1 Features 4 1 1 Super Energy Saving ...
Page 8: ...8 ...
Page 9: ...9 4 1 2 Super Keep Fresh Vitamin Safe ...
Page 10: ...10 ...
Page 11: ...11 ...
Page 12: ...12 4 1 3 Super Hygienic ...
Page 13: ...13 4 2 Functions 1 2 3 4 ...
Page 14: ...14 5 6 7 8 ...
Page 21: ...21 6 Location of Controls and Components 6 1 Display and Control Panel ...
Page 22: ...22 6 2 Components ...
Page 23: ...23 7 Installation Instructions 7 1 Installation Instructions ...
Page 24: ...24 7 2 Getting started ...
Page 25: ...25 ...
Page 29: ...29 10 Troubleshooting Guide 10 1 FC and PC not cooling at all Compressor does not run ...
Page 30: ...30 10 2 PC is not cooling or poor cooling FC cooling condition is normal ...
Page 31: ...31 10 3 FC is poor cooling Compressor run ...
Page 32: ...32 10 4 VC is poor cooling or excessive cooling ...
Page 50: ...50 12 Maintenance 12 1 Automatic Defrosting 12 2 Removing and attaching shelves ...
Page 51: ...51 12 3 Care and cleaning instructions ...
Page 52: ...52 ...
Page 53: ...53 13 Dimensions 13 1 Outside NR B30FX1 NR B30FG1 ...
Page 54: ...54 13 2 Inside NR B30FX1 ...
Page 55: ...55 13 3 Inside NR B30FG1 ...
Page 56: ...56 14 Schematic Diagram 14 1 Schematic Diagram NR B30FG1 NR B30FX1 ...
Page 57: ...57 14 2 Wiring Diagram NR B30FG1 NR B30FX1 ...
Page 58: ...58 15 Exploded View and Replacement Parts List 15 1 Exploded View 1 NR B30FG1 NR B30FX1 ...
Page 59: ...59 15 2 Replacement Parts List 1 NR B30FG1 NR B30FX1 ...
Page 60: ...60 15 3 Replacement Parts List 1 NR B30FG1 NR B30FX1 ...
Page 61: ...61 15 4 Exploded View 2 NR B30FG1 NR B30FX1 ...
Page 62: ...62 15 5 Replacement Parts List 2 NR B30FG1 NR B30FX1 ...
Page 63: ...63 15 6 Replacement Parts List 2 NR B30FG1 NR B30FX1 ...
Page 64: ...64 15 7 Exploded View 3 NR B30FG1 NR B30FX1 Bundled parts The parts for left opening doors ...
Page 66: ...66 15 9 Packing Exploded View NR B30FG1 NR B30FX1 ...
Page 67: ...67 15 10 Packing Material Pats List NR B30FG1 NR B30FX1 ...