4.4.2. NN-ST677M, ST667W
SYMPTOM
STEP
CHECK
RESULT
CAUSE/CORRECTIONS
No display when oven is first plugged
in
1
Fuse pattern of D.P.C.
Normal
→
Step2
Open
Replace D.P.C. or Fuse
Pattern
2
Low voltage transforment (L.V.T.)
secondary voltage
Abnormal 0V
L.V.T.
Normal
→
Step3
3
IC1 pin23 voltage
Abnormal
ZD11, Q11, ZD10, Q10
Normal=3.3V
IC1, CX320, Display
No key input
1
Membrane switch continuity
Abnormal
Membrane switch
Normal
IC1
No beep sound
1
IC1 pin 29 voltage
Abnormal
IC1
Normal=3.3V
BZ310, Q224
Power relay A(RY2) does not turn on
even though the program had been set
and the start pad is tapped
1
IC1 pin 2 voltage while operation
Abnormal
IC1
Normal=3.3V
→
Step2
2
Collector of Q223
Abnormal
Q223
Normal 0.7V
RY2
No microwave oscillation at any power
1
IC1 pin 1 voltages while operation at high
power
Abnormal
IC1
Normal=3.3V
→
Step2
2
Collector of Q220
Abnormal
Q220, Q225
Normal 0.7V
→
Step3
3
Short circuit between collector of Q220
and emitter of Q225
Still not turn on
RY1
RY1 turns on
Q221, Q222
Dark or unclear display
1
Replace display and check operation
Normal
Display
Abnormal
IC1
Missing or lighting of unnecessary
segment
1
Replace IC1 and check operation
Normal
IC1
Abnormal
Display
H95/H97/H98 appears in window and
oven stops operation.Program High
power for 1 minute and conduct
following test quickly, unless
H95/H97/H98 appears and oven stops
1
Unplug CN702 (2 pin) connector and
measure voltage between terminals
Abnormal=0V
1. Latch Switch
2. D.P.C. /Power Relay
Normal=220~240V
→
Step2
2
Unplug CN701 (3 pin) connector and
measure pin3 voltage
Abnormal=0V
D.P.C.
Approx. AC 3V
Magnetron
4.5. Simple way of H.V. Inverter/magnetron troubleshooting
Purpose:
Simple way
(3/38 seconds rule)
of identifying whether it’s Magnetron, Inverter or others.
Set-up:
The unit under question is connected through the Ammeter as shown below.
Procedure:
Follow the matrix table below to identify the problem source.
Note:
Do not replace both Inverter board and Magnetron simultaneously and automatically without going through this
procedure.
Power will:
Ammeter reading is:
To do:
Remedy:
Shut off in 38 seconds
after “Start”.
1. Between 0.5A and 1.0A.
Check and repair open magnetron circuit Open magnetron wiring between Inverter
and magnetron terminal.
2. Between 1.0A and 2.0A.
Check continuity of D702 in Inverter PCB.
1. D702 shorted
Replace
H.V.Inverter
(F606YM300BP)
2. D702 is OK
Replace
magnetron
Shut off in 3 seconds
after “Start”
1. Less than 0.5A
Check open circuit: Latch Switch, DPC,
Power Relay and CN701
Replace
defective
component(s),
or
correct switch, cables and connectors.
13
NN-ST657S / NN-ST677M / NN-ST667W / NN-ST657W
Summary of Contents for NN-ST657S
Page 2: ...2 NN ST657S NN ST677M NN ST667W NN ST657W ...
Page 3: ...3 NN ST657S NN ST677M NN ST667W NN ST657W ...
Page 5: ...1 SCHEMATIC DIAGRAM 5 NN ST657S NN ST677M NN ST667W NN ST657W ...
Page 15: ...5 EXPLODED VIEW AND PARTS LIST 5 1 EXPLODED VIEW 15 NN ST657S NN ST677M NN ST667W NN ST657W ...
Page 23: ...6 DIGITAL PROGRAMMER CIRCUIT 6 1 NN ST657S ST657W 23 NN ST657S NN ST677M NN ST667W NN ST657W ...
Page 24: ...24 NN ST657S NN ST677M NN ST667W NN ST657W ...
Page 25: ...6 2 NN ST677M ST667W 25 NN ST657S NN ST677M NN ST667W NN ST657W ...