RATED OUTPUT
TEMPERATURE RISE
1200W
Min. 18.5°F(10.3°C)
1300W
Min. 19.8°F(11.1°C)
3. PROCEDURE FOR MEASURING MICROWAVE
ENERGY LEAKAGE
NOTE:
The U.S. Government standard is 5 mW/cm
2
while in the customer’s
home. 2mW/cm
2
stated here is our own voluntary standard. (1mW/cm
2
for Canada)
3.1. Equipment
- Electromagnatic radiation monitor
- Glass thermometer 212°F or 100°C
- 600cc glass beaker
3.2. Procedure for measuring radiation leakage
Note before measuring.
- Do not exceed meter full scale deflection. Leakage monitor should
initially be set to the highest scale.
- To prevent false readings the test probe should be held by the grip
portion of the handle only and moved along the shaded area in Figure
no faster than 1 inch/sec (2.5cm/sec).
- Leakage with the outer panel removed ...... less than 5mW/cm
2
.
- Leakage for a fully assembled oven with door normally closed ...... less
than 2mW/cm
2
(1mW/cm
2
for Canada).
- Leakage for a fully assembled oven [Before the latch switch (primary) is
interrupted] while pulling the door ...... less than 2mW/cm
2
.
1. Pour 275 ± 15cc (9ozs
s
± 1/2oz) of 20°C ± 5°C (68° ± 9°F) water in a
beaker which is graduated to 600cc, and place in the center of the oven.
2. Set the radiation monitor to 2450MHz and use it following the
manufacturer's recommended test procedure to assure correct results.
3. When measuring the leakage, always use the 2 inch (5cm) spacer
10
Summary of Contents for NN-SN776S
Page 3: ...3...
Page 4: ...4...
Page 5: ...5...
Page 6: ...1 SCHEMATIC DIAGRAM 1 1 APH 1 2 CPH 6...
Page 7: ...2 MEASUREMENTS AND ADJUSTMENTS 7...
Page 14: ...specified parts NOTE A parts are supplied by CSD Japan F parts are supplied by PHAMOS China 14...
Page 22: ...22...
Page 23: ...7 2 NN SN756S APH 23...
Page 24: ...24...
Page 25: ...7 3 NN SN756B APH SN756BT APH SA746M APH 25...
Page 26: ...26...