2.6 Confirm after repair
1. After repair or replacement of parts, make sure that the screws of the oven, etc. are neither loose nor
missing. Microwaves might leak if screws are not properly tightened.
2. Make sure that all electrical connections are tight before inserting the plug into the wall outlet.
3. Check for microwave energy leakage. (Refer to procedure for measuring microwave energy leakage).
CAUTION MICROWAVE RADIATION
USE CAUTION NOT TO BECOME EXPOSED TO RADIATION FROM THE MICROWAVE MAGNETRON
OR OTHER PARTS CONDUCTING MICROWAVE ENERGY
IMPORTANT NOTICE
The following components have potentials above 2000V while the appliance is operated.
Magnetron
High voltage transformer (Located on inverter (U))
High voltage diodes (Located on inverter (U))
High voltage capacitors (Located on inverter (U))
Pay special attention to these areas.
When the appliance is operated with the door hinges or magnetron installed incorrectly, the microwave leakage
can exceed more than 5mW/cm2. After repair or exchange, it is very important to check if the magnetron and
thedoor hinges are correctly installed.