21
10.5.
Inverter Power Supply
Caution
DO NOT try to repair this inverter power supply). Replace as a whole H.V. Inverter Unit.
Figure 3
Inverter Power Supply Diagram
10.6.
Inverter Power Supply Unit
Warning
Do not attempt to make any measurements in the high volt-
age circuitry of the inverter or magnetron.
See troubleshooting of the inverter circuit and magnetron on
Figure 4 to determine if the inverter power supply is still func-
tioning.
10.7.
Temperature Sensor
A temperature sensor is mounted on the oven cavity on the
right hand side. The resistance reading across the thermistor
should read 300K ohm within a temperature range of 10 to 30
degrees centigrade. This would be the temperature range
within a kitchen environment. If the resistance measured is out-
side this range the thermistor is defective and should be
replaced.
NOTE: When measuring the resistance of the thermistor dis-
connect the connector from the digital programmer circuit.
NOTE: If the microwave oven has been operated allow to cool
to room temperature before attempting to measure the ther-
mistor resistance.