DISPLAY
CONDITIONS
POSSIBLE CAUSE
TIMING OF FAILURE INDICATION
F33
Open temperature
sensor (exhaust)
1. Temperature sensor failure
2. Digital programmer circuit failure
3. Loose connector CN5
It is appeared when failure
occurred.
F34
Short temperature
sensor (exhaust)
1. Temperature sensor failure
2. Digital programmer circuit failure
It is appeared when failure
occurred.
F44
1. Shorted power select switch
2. Shorted membrane switch
It is appeared 2 minutes after
failure occurred.
F01 / (With
continuous
beep sounds)
Exhaust
temperature
exceeds 120°C
1. Burning food in the oven due to over cook
It is appeared when exhaust
temperature exceeds above
120°C.
F03
Input voltage
12.5%
1. Increase in power source voltage
It is appeared when the unit is
plugged in. Note that it returns
normal operation mode by
tapping the RESET pad ( ).
F04
Input voltage is
less than — 12.5%
1. Decrease in power source voltage
It is appeared when the unit is
plugged in. Note that it returns
normal operation mode by
tapping the RESET pad ( ).
F05
Memory failure
1. Digital programmer circuit failure
No display
1.25/3A fuse blown
1. Switch failure (short switch)
2. Low-Voltage transformer failure
No display
1.25/3A fuse is OK
1. Thermal cutout failure
2. Low voltage transformer failure
3. Digital programmer circuit failure
F81
No voltage supply
to high voltage
trans. (lower/left)
1. Relay failure RY-3 (A)
2. Loose connector CN256, CN257
3. Digital programmer circuit failure
It is appeared when failure
occurred.
F82
No voltage supply
to high voltage
trans. (lower/right)
1. Relay failure RY-5 (B)
2. Loose connector CN258, CN259
3. Digital programmer circuit failure
It is appeared when failure
occurred.
F83
No voltage supply
to high voltage
trans. (upper/left)
1. Relay failure RY-7 (C)
Loose connector CN260, CN261
2. Digital programmer circuit failure
It is appeared when failure
occurred.
F84
No voltage supply
to high voltage
trans. (upper/right)
1. Relay failure RY-9 (C)
Loose connector CN262, CN263
2. Digital programmer circuit failure
It is appeared when failure
occurred.
F86
Shorted contacts
of RY-3
1. Replay failure RY-3 (A)
2. Digital programmer circuit failure
It is appeared when failure
occurred.
F87
Shorted contacts
of RY-5
1. Replay failure RY-5 (B)
2. Digital programmer circuit failure
It is appeared when failure
occurred.
F88
Shorted contacts
of RY-7
1. Replay failure RY-7 (C)
2. Digital programmer circuit failure
It is appeared when failure
occurred.
F89
Shorted contacts
of RY-9
1. Replay failure RY-9 (D)
2. Digital programmer circuit failure
It is appeared when failure
occurred.
[TROUBLE]Oven does not operate at all or oven does not start cooking. NE-2180, NE-2140
33
Created with novaPDF Printer (
www.novaPDF.com
). Please register to remove this message.
Summary of Contents for NE-2140
Page 1: ...Mod NE3240 Production code NE3240 09 2012 ...
Page 5: ...4 Created with novaPDF Printer www novaPDF com Please register to remove this message ...
Page 6: ...5 Created with novaPDF Printer www novaPDF com Please register to remove this message ...
Page 25: ...24 Created with novaPDF Printer www novaPDF com Please register to remove this message ...
Page 36: ...35 Created with novaPDF Printer www novaPDF com Please register to remove this message ...
Page 47: ...46 Created with novaPDF Printer www novaPDF com Please register to remove this message ...
Page 50: ...49 Created with novaPDF Printer www novaPDF com Please register to remove this message ...
Page 51: ...50 Created with novaPDF Printer www novaPDF com Please register to remove this message ...
Page 54: ...53 Created with novaPDF Printer www novaPDF com Please register to remove this message ...