17
Mesh filter
●
If it cannot be recovered or feel something strange, disconnect the plug, reconnect after 30
seconds and operate it again.
●
Inside lid may turn yellow, but no harm for operation.
●
“Clickety-clack” sound caused when open and close the lid is the sound caused by the valve
swing to prevent the hot water run off.
●
Outside body becomes 45°C while warm keep if the room temperature is high.
The unit doesn’t
turn on electricity.
●
It is broken if the electric
components are taken in
water. Contact the stores
where you purchased
for repair.
●
You poured in water directly from a tap.
●
You put the unit on the sink.
●
You turned the unit upside down with
its bottom wet.
●
You washed the unit in water.
Replacement of Parts
Replacement of Parts
Replace gaskets if they crack, lose their pliancy
or, for any other reasons which allow steam to
escape from between the container and the lid.
Replace the filter, if foreign materials which
clog the filter cannot be removed, even after
you scrub with a cleaning brush, etc.
Lid cover
Set gaskets
Consumable parts are available from an
authorized dealer.
Part name
Part No.
Rubber gasket set
APH65-613-0S
Mesh filter
APB97-480-0U
Charcoal filter
APC58H628-0U
Remove lid, unscrew 3 tapping screws and
remove the lid cover.
Exchange the gaskets and then place the lid
cover back and secure with the tapping screws.
Charcoal filter
The indicator lights flash
alternately and displayed
.
●
This is malfunction of the sensor. Contact the stores where you purchased.
Rough replacement period : 1 year
Rubber gasket set
NC-HU401_301-EN+CH-1.indd 17