— 8 —
NC-HU301P, NC-HU401P
3.4 Check points
3.4.1. Picture is the case of 3.0L
To peg frame
Electric pump
Turn the power on press
the Lock/Unlock key for
unlocking, for unlocking,
press the Pour Out key to
on, and confirm the motor
rotating sound.
Red
White
Blue
Orange
Red
Red
Red
Thermal fuse (Completed)
(Between
-
: 0
Ω
)
Boiling heater
(Between
-
• Orange
Approx.58
Ω
)
Keep warm heater
(Between
-
•
Orange Approx.432
Ω
)
Lead wire E
(Completed)
(0
Ω
)
Thermistor (Completed)
Approx. 20°C
Approx 45k
Ω
Blue
1
3
2
3
5
1
2
3
4
4
5