![Panasonic NC-HU301P Service Manual Download Page 14](http://html.mh-extra.com/html/panasonic/nc-hu301p/nc-hu301p_service-manual_270369014.webp)
— 14 —
NC-HU301P, NC-HU401P
3.6.5. Keep warm (When want to reboil from 90 Keep warm)
(Long Boil/Reboil LED : Blink)
Boiling detection after 2 minutes
(Long Boil/Reboil LED : OFF)
Press Long Boil/Reboil
pad 2 times
Extend boiling approx.
6 minutes
Boiling detection after
2.5 to 5 minutes
After 3 minutes.
After approx.
2.5 to 4.5 hours
If the water is added, check the Long Boil/Reboil LED lighted on. If does not light on, press the Long Boil/Reboil LED.
There may be not start boiling automatically.
In this case, switches to Keep warm after once boiled. (Measure for unwanted bacteria)
Initial setting of Keep warm is 90 when power on.
3.6.6. Cleaning (When cleaning with citric acid from the water)
(Long Boil.Reboil LED : Lighted)
(Rotating Cleaning sign lighted)
Keep warm LED,
8
sign and
sign blink at the same time
When power ON.
(Long Boil/Reboil LED : Lighted)
Press Slect pad and
set to Cleaning
After approx. 31 to 32
min. from normal water
temperature.
3.6.7. Detection of Abnormal Operation
Themistor disconnection
(Long Boil/Reboiling, Keep
warmLEDs blink alternately.
No-water boiling or abnormal
temperature (Long Boil/Reboiling,
Keep warm LEDs blink alternately.