4 Slide portion of the geared motor shall be removed
the coupler.
Mechanism
case
1 Remove 2 screws mounting the body B.
2 Hold the body B, and pull the rear portion upward
slightly.
And slide the body B frontward as shown in figure.
(Holding pawls at front portion)
3 Remove the feed hose and Air supply hose from the
outer tub cover.
4 Set the body B against a wall.
5 Remove 4 screws mounting the outer tub cover to
remove it.
6 Remove the pulsator.
12