22
3
Pull heater out gently holding both sides.
10.16. Twinjet System
1
2
Remove twinjet hoses from tub bellow seal pulling
them up
Remove screw fixing circulation pump
3
4
Lay the appliance down and press on ratchet holding
circulation pump
Remove circulation pump
5
6
Remove cable connector
Remove hose connecting circulation pump to drain pump
Summary of Contents for NA-147VB6WDE
Page 2: ...2 ...
Page 4: ...4 2 3 Dimension in millimetres NA 147VB6 ...
Page 5: ...5 3 Location of Controls and Components ...
Page 9: ...9 5 2 Program Details ...