41
11.9. Circulation Pump
The component is used for circulation of water inside the
drum in order to increase washing performance.
Technical features
Nominal voltage 220-240 V
Frequency 50 Hz
Resistor (coil) 169,5
(±5%)
Testing component
Check the resistance value on the component with multimeter as shown below.
Resistance value should be between 160 - 180
You can determine the ohm value by measuring from the red cable at 5th and red cable at 12th position in the small socket
(refer wiring diagram in section 12) as shown below figure. Resistance value should be between 160 - 180
Component test