background image

3

2

 CAUTION

 DANGER

Do not touch the rotating part of the motor 

while operating.

  The failure could result in injuries.

Ground the earth of the brushless motor and 

brushless amplifier.

  

The failure could result 

in electric shocks.

Do not expose the cables to sharp objects,

excessive pressing or pinching forces, and 

heavy loads.

 

 

The failure could result in electric 

shocks, damages, or malfunction.

Install an external emergency stop device 

to shut down the main power source in any 

emergency.

  

The failure could result in electric shocks, 

injuries, fire, damages or malfunction.

Do not place inflammable matter near the motor, 

amplifier and external regenerative resistor.

  The failure could result in fire.

Mount the brushless

 

motor, brushless 

amplifier and external regenerative resistor on 

incombustible material such as metal.

  

The failure could result 

in electric shocks, injuries, or fire.

Arrange the phase sequense of the motor and 

wiring of the CS sensor.

  

The failure could result 

in injuries, damages, or malfunction.

Do not climb or stand on the brushless 

equipment.

 

 

The failure could result in electric shocks, 

injuries, damages, or malfunction.

Make sure to secure the safety after the 

earthquake.

  

The failure could result 

in electric shocks, injuries, or fire.

Do not approach to the equipment after 

recovery from the power failure because they 

may restart suddenly.

 

 

The failure could result in injuries.

Do not hold the cables or motor shaft when 

transporting the motor.

  The failure could result in injuries.

Do not touch the motor, amplifier, and external 

regenerative resistor, since they become hot.

  The failure could result in burns.

An over-current protection, earth leakage 

breaker, over temperature protecter and 

emergency stop device must be installed.

  

The failure could result 

in electric shocks, injuries, or fire.

Transportation, wiring and checking must 

be performed with power source turned off 

and after making sure that there is no risk of 

electric shock.

  

The failure could result 

in electric shocks or injuries.

Do not subject the product to water, corrosive 

or flammable gases, and combustibles.

  The failure could result in fire.

Install the product properly to avoid personal 

accidents or fire in case of an earthquake.

  

The failure could result 

in electric shocks, injuries, or fire.

Do not connect the cable (U, V and W) of the 

brushless motor directly to the commercial 

power source.

 

 

The failure could result 

in fire, malfunction or damage.

Do not put your hands in the brushless 

amplifier.

 

 

The failure could result in burns, 

or electric shocks.

Only persons who are trained and qualified

to work with or on electrical equipment are 

permitted to operate or maintain this equipment.

  

The failure could result 

in electric shocks.

Do not drive the motor from the external power.

  The failure could result in fire.

Never start and stop the motor by magnet 

contactor which is provide on the main line.

  The failure could result in damages.

Safety Precautions

Important

The following explanations are for things that must be observed in order to 

prevent harm to people and damage to property.
• Misuses that could result in harm or damage are shown as follows, classified 

according to the degree of potential harm or damage.

Danger

Indicates great possibility of death or serious 

injury.

Caution

Indicates the possibility of injury or property 

damage.

• The following indications show things that must be observed.

Indicates something that must not be done.

Indicates something that must be done.

Summary of Contents for MINAS-BL KV Series

Page 1: ... after reading and read as necessary Be sure to give this Instruction manual to an end user Label of safety precaution is affixed to the product If you are the first user of this product please be sure to read the instruction Manual Overall from our Web Site Web address of Panasonic Corporation http industrial panasonic com ww i_e 25000 motor_fa_e motor_fa_e html This product image is 200 W type o...

Page 2: ...urrent protection earth leakage breaker over temperature protecter and emergency stop device must be installed The failure could result in electric shocks injuries or fire Transportation wiring and checking must be performed with power source turned off and after making sure that there is no risk of electric shock The failure could result in electric shocks or injuries Do not subject the product t...

Page 3: ...ght this product Checking the model of Amplifier and Motor This amplifier is designed for use in combination with a motor to be specified by us Check a name of series rated output voltage specifications you wish to use You must not use any other combinations than those listed below Standard Voltage Out put Amplifier Type Applicable Motor Single phase AC100 to 120 V 50 W MBEK5A1BCV MBMS5AZBL 100 W ...

Page 4: ...otor in corrosive atmosphere such as hydrogen sulfide sulfurous acid chlorine ammonia sulfur gas chloride gas sulfide acid alkali and salt in the atmosphere of combustible gas or in the vicinity of flammables 3 Place not exposed to grinding liquid oil mist iron powder and cutting particle 4 Well ventilated place with little moisture oil or inundation and place far from heat source such as a furnac...

Page 5: ...supply outside of equipment from MCCB use an electric wire of 1 6 mm diameter 2 0 mm2 or more both for main circuit and grounding Apply grounding class D 100 Ω or below for grounding Do not tighten the ground wires together but connect them individually Fastening torque of earth screws to be 0 49 to 0 98 N m For details of parameters refer to the Instruction Manual Overall For the wiring of commun...

Page 6: ...ation Connection of digital key pad of an option is possible digital key pad connecting cable of an option DV0P383 is required The terminal number of a modular jack is the following figure 8 1 Refer to operation manual Overall for the correspondence procedure of RS485 1 Do not connect anything 2 5 V DC5 V power supply for digital key pad 3 SOT Interface for digital key pad or PANATERM for BL 4 SIN...

Page 7: ...fier Conformance to EC directive and UL standard Conformance to EC directive and UL standard Configuration of peripheral equipment Power supply 100 V system Single phase 100 V to 120 V 10 50 60 Hz 200 V system Single phase 3 phase 200 V to 240 V 10 50 60 Hz Use the equipment under the environment of overvoltage category II specified by IEC60664 1 In order to obtain overvoltage category III insert ...

Page 8: ...void inputting a supply voltage which significantly exceeds the rated range to the power supply of this product Failure to heed this caution may result in damage to the internal parts causing smoking and or a fire and other trouble Item Specifications Model name Brushless amplifier MBEK 5A1BCV MBEK 5A5BCV MBEK 011BCV MBEK 015BCV MBEK 021BCV MBEK 025BCV MBEK 045BCV MBEK 083BCV Brushless motor MBMS5...

Page 9: ... can be downloaded from the following web site http industrial panasonic com ww i_e 25000 motor_fa_e motor_fa_e html Pursuant to at the directive 2004 108 EC article 9 2 Panasonic Testing Centre Panasonic Marketing Europe GmbH Winsbergring 15 22525 Hamburg F R Germany 7 1 1 Morofuku Daito Osaka 574 0044 Japan Phone 81 72 871 1212 For your records The model number and serial number of this product ...

Reviews: