Size F 200 V
Use terminal blocks.
Terminal
No.
(Upper to
bottom)
Terminal
symbol
Name
Description
Term
in
al
b
lo
ck
1
L1
Main power input
terminal
3 phase 200 - 240 V
+ 10 %
- 15 %
50/60 Hz
2
L2
3
L3
4
L1C
Control power
input terminal
Single phase
200 - 240 V
+ 10 %
- 15 %
50/60 Hz
5
L2C
6
P
Regenerative
resistor connecting
terminal
Normally, short out the circuit between B and RB.
To use an external regenerative resistor (customer prepared), open between RB
and B and connect an external regenerative resistor between P and B.
In addition, parameter setting is required for the regenerative resistor.
For details, refer to "Technical Reference - Functional Specification ".
Do not connect anything to the N terminal.
7
RB
8
B
9
N
10
U
Motor output
terminal
Connect each phase of the motor winding.
U: U phase V: V phase W: W phase
11
V
12
W
Earth
Earth terminal for grounding
* Tighten the Earth screw with a torque of m, M5: 1.8 to 2.0 N · m.
* Tighten the terminal block screws with a torque of M5: 1.8 to 2.0 N · m.
* Tighten the fixing for the terminal block cover screws with a torque of M3: 0.19 to 0.21 N · m.
* The screws may be damaged if the tightening torque has exceeded the maximum value.