4.2 Pr0.00 (Motor rotation direction)
Parameter
Range
Description
Pr0.00
0 or 1
Motor rotation direction
Pr0.06
0 or 1
Counting direction of the command pulses
Pr0.07
0 to 3
Input mode of the command pulses
Pr0.08
0 to 1048576 [pulse] (MINAS A5)
0 to 8388608 [pulse] (MINAS A6)
Number of pulse signals per motor
revolution
Pr0.09
0 to 1073741824
Gear ratio numerator
Pr0.10
1 to 1073741824
Gear ratio denominator
Pr5.32
250 to 4000 [kHz] (MINAS A5)
250 to 8000 [kHz] (MINAS A6)
Maximum pulse input frequency
4.2
Pr0.00 (Motor rotation direction)
PANATERM parameter: “Rotational direction setting”
Setting range: 0 or 1
The default value is 1: Rotation in CCW direction (counterclockwise direction).
4.3
Pr0.01 (Control mode)
PANATERM parameter: “Control mode setting”
Setting range: 0 to 6
The default value is 0: Position control
Select 0: Position control
4.4
Pr0.06 (Counting direction of the command pulses)
PANATERM parameter: “Command pulse rotational direction setup”
Setting range: 0 or 1
The default value is 0: Positive counting direction = B leads A, SIGN input, logical high
signal.
In combination with Pr0.07, you can select up to 6 command pulse input formats. Please
refer to the parameter description in the
Operating Instructions (Overall) AC Servo Motors &
Operating Instructions (Overall) AC Servo Motors & Driver MINAS
for details.
QS2000_V1.1_EN