- 20 -
System Configuration and Wiring
List of Available Components
As these models with * are used for both 1-phase 200V and 3-phase 200V, make a choice
according to the power source.
• When these wires are used, wire length between circuit breaker and amplifier should be less than 3 m.
• The model numbers of circuit breaker and magnetic contactors shown in the above list are manufactured by
Matsushita Electric Works, Ltd.
• Use the circuit breaker as shown in App.3 to meet relevant EC Directives.
• The model number of noise filters (options) shown in the above are manufactured by Okaya Electric Industries
Co., Ltd.
<Notes>
• CN POWER, CN MOTOR and earth terminals
Wires should be copper conductors of a temperature rating of 60˚C or above.
• Earth wire diameter should be 2.0 mm
2
(AWG14) or larger.
• Please also consider the electrochemical potentials between metal conductor including closed loop terminals.
The electrochemical potentials shall be less than 0.6V.
Magnetic contactor
( c o n t a c t s )
B M F T 6 1 0 4 1 N
( 3 P + 1 a )
B M F T 6 1 5 4 1 N
( 3 P + 1 a )
B M F T 6 1 5 4 1 N
( 3 P + 1 a )
M M F T 6 1 0 4 2 N
( 3 P + 1 a )
Noise
filter
D V O P 1 4 4 1
D V O P 1 4 4 2
D V O P 1 4 4 1
D V O P 1 4 4 2
D V O P 1 4 4 1
D V O P 1 4 4 2
Circuit
breaker
(rated current)
B K 2 5 1
( 5 A )
B K 2 1 0 1
( 1 0 A )
B K 3 5 1
( 5 A )
B K 3 1 0 1
( 1 0 A )
B K 3 5 1
( 5 A )
B K 3 1 0 1 ( 1 0 A )
B K 3 1 5 1
( 1 5 A )
Required Power
(at the rated load)
Approx. 0.3kVA
Approx.
0.4kVA
Approx.
0.5kVA
Approx.
1.0kVA
Approx.
0.3kVA
Approx.
0.5kVA
Approx.
0.9kVA
Approx.
0.3kVA
Approx.
0.5kVA
Approx. 0.9kVA
Approx.
1.3kVA
Output
30 ~ 50W
1 0 0 W
2 0 0 W
4 0 0 W
30 ~ 50W
1 0 0 W
2 0 0 W
4 0 0 W
30 ~ 50W
1 0 0 W
2 0 0 W
4 0 0 W
7 5 0 W
Voltage
1-phase,
1 0 0 V
*1-phase,
2 0 0 V
1-phase,
2 0 0 V
*3-phase,
2 0 0 V
3-phase,
2 0 0 V
Main circuit wire diameter
(L1 , L2, L3,
U, V, W, E)
0.75mm
2
~ 0.85mm
2
AWG 18
Series
M U D S
A m p l i f i e r