3 Troubleshooting Guide
CONDITION
CHECK POINT
METHOD OF INSPECTION
TRANSACTION
Motor fails to rotate
(no noise is heard at all)
Power supply cord
Check power supply cord continu-
ity.
If there is no continuity, replace the
cord reel patition unit.
Fuse of P.C.B. Ass’y
(250V, 10A)
Check fuse continuity.
If there is no continuity, replace
P.C.B. Ass’y.
Motor continuity
Check the conduction between the
terminals of the motor.
If there is no continuity, replace the
or motor.
ON/OFF
Switch
Check continuity across switch
connections
If there is no continuity, replace
P.C.B. Ass’y.
P.C.B. Ass’y
Check the internal parts for any-
thing unusual. (burn-out, melt-
down, etc.)
If anything is found unusual,
replace the P.C.B. assembly with
new one.
Motor runs but there is no suction Hose or Suction inlet, Extension
wand and nozzle
Check whether or not the specified
components are clogged with for-
eign substances.
If there is any blockage, remove it.
Dust bog / Secondary filter
Check if dust bag is full or Second-
ary filter is choked up.
If dust bag is foll, replace with a
new one. If Secondary filter is
choked up, remove and clean it out
or replace.
Noise or vibration
Motor fan
Check dust accumulated in motor
fan (it could happen if the vacuum
cleaner has been used without cen-
tral filter).
If there is dust accumulated in the
motor fan, replace the motor and
check filter condition. (never try to
dismantle the motor fan)
The motor output cannot be
changed.
(The motor rotation does not
change.)
(The motor always rotates at full
speed.)
Output controller
Adjust the output controller and
check whether or not the resistance
varies.
If the resistance value does not
change, then replace the P.C.B.
ass'y.
P.C.B. ass’y
Check whether or not T1 and T2 of
the Triac on the P.C.B. ass'y are
short-circuited.
If they are short-circuited, then
replace the P.C.B. ass'y.