Wiring
Maintenance/inspections/ How to reset a trip
• GP series
Connector on amplifier side: Parts No. S10B-PASK-2 (J.S.TMfg.,Co.,Ltd.) or equivalent.
mating connector: Representative Housing PAP-10V-S,
(
Terminal SPHD-001T-P0.5 or SPHD-002T-P0.5
)
Terminal
number
Terminal
symbol
Terminal
name
Default
Terminal explanation
function
selection
logic
selection
1
I
1
*1
Signal
input 1 Run start
In turning on signal, short between “
I
1”
and “GND”.
*2
Pr50
Pr54
2
I
2
*1
Signal
input 2
Point
designation
In turning on signal, short between “
I
2”
and “GND”.
*2
Pr51
Pr55
3
I
3
*1
Signal
input 3
Home
sensor
In turning on signal, short between “
I
3”
and “GND”.
*2
Pr52
Pr56
4
(NC)
—
—
Do not connect anything.
—
—
5
I
4
*1
Signal
input 4
Forced
trip
In turning on signal, short between “
I
4”
and “GND”.
*2
Pr53
Pr57
6
GND Control
ground
—
Common ground terminal for control
signal.
—
—
7
(NC)
—
—
Do not connect anything.
—
—
8
+5V Power
supply
—
Set 50 mA or below
—
—
9
01
*1
Signal
output 1 Trip output
Open collector output.
Open collector Vce max: DC30 V,
Ic max: 50 mA
Pr5C Pr5E
10
02
*1
Signal
output 2
In-motion
signal
Open collector output.
Open collector Vce max; DC 30 V,
Ic max; 50 mA
Pr5d
Pr5F
*1 Function of input/output can be changed by PANATERM for BL and the Digital key pad.
Default is shown.
*2 Maximum rated voltage: –0.5 to 5.5V.
• Connector for control signals pin number is 1, 2, ... 10 in the order from grounding terminal side.
• Permissible length for control signal cable is 5m or less.
Connector for comunications (SER)
Modular jack: 85503-0001 (Japan Molex Inc.) or equivalent (RJ45)
Terminal
number
Terminal
Symbol
Terminal explanation
• Connection of digital key pad of
an option is possible. digital key
pad connecting cable of an option
(DV0P383**) is required.
• The terminal number of a modular
jack is the following
figure
8
1
• Refer to operation manual
(Overall) for the correspondence
procedure of RS485.
1
—
Do not connect anything.
2
+
5 V
DC5 V power supply for digital key pad
3
SOT
Interface for digital key pad or
PANATERM for BL
4
SIN
5
RS485+ for connect RS485+
6
RS485− for connest RS485–
7
GND
power supply GNG for Digital key pad
8
SCK
Interface for digital key pad
Maintenance/ inspections
Routine maintenance and inspection are essential for proper and satisfactory operation of
the motor.
Maintenance/ Inspection item
Maintenance/
Check item
Inspection
procedure
Condition
Input voltage Voltmeter Must be within ±10% of rating.
Input current Ammeter Must be within rated input current described on nameplate.
Insulation
resistance
Insulation
resistance
tester
Measure the insulation resistance with 500 V Megger. It must be
above 1 MΩ.
Measuring position: Between power input line (L1, L2,L3) and
grounding wire
Noise
Hearing
Noise level must not be different from the usual level. In addition,
abnormal noise such as rumbling noise must not be heard.
Vibration
By hand
Free from abnormal vibration.
Installation
bolt
Torque
wrench
Check for loosening of bolt, and tighten additionally as necessary.
Use
environment
By sight
Check the ambient temperature and humidity, and make sure that
dirt, dust, or foreign substance is not found.
check the waste thread etc don’t attached to the windhole of brushless
amplifier.
Caution
• Power-on/off operations should be done by the operators themselves for ensuring safety
in checking.
• Do not touch the motor while it is running or immediately after it stops because it gets hot
and stays hot for a while after power has been turned off.
• The DC500 V megger testing should be performed only on the main circuit. Be sure to
disconnect the power supply. Otherwise, failure will occur. The resistance should be 1
MΩ between the ground with L1, L2 and L3 short-circuited.
When disassembly, troubleshooting, etc., is needed,
be sure to contact our service department or the sales agent of purchase.
How to clear trip
If the motor trips (alarm LED is lit), remove the cause and use one of the following clearing
procedures.
• Turn off power, and when the power LED goes off, turn on power again.
• For clearing procedure using the panel B or an input terminal, refer to the Instruction
Manual (Overall).
<CAUTION>
Before clearing the trip, be sure to locate and remove the cause.