background image

5

4

 CAUTION

Do not subject the brushless amplifier, motor 

or shaft to high impact.

  The failure could result in malfunction.

If trip occurs, remove the causes of the trip and

secure the safety before restarting.

  The failure could result in injuries.

Execute the trial-operations with the motor fixed 

and a load unconnected. Connect a load to the 

motor after the successful trial-operations.

  The failure could result in injuries.

Use the specified voltage on the product.

  

The failure could result 

in electric shocks, injuries, or fire.

Install a safety device against idling or locking 

of gear head, and leakage of grease.

  

The failure could result in injuries, 

damages, and contaminations.

Do not modify, dismantle or repair the product.

 

 

The failure could result 

in electric shocks, injuries, or fire.

Do not block the heat dissipation hole.

 

 

The failure could result 

in electric shocks, or fire.

Maintenance and check must be performed by 

an expert.

  

The failure could result 

in injuries and electric shock.

Conduct proper installation according to 

product weight or rated output.

  

The failure could result 

in injuries, or damages.

Use the motor and amplifier with the specified 

combination.

  The failure could result in fire.

Ambient temperature of installed motor and 

amplifier should be under permittable one.

  The failure could result in damages.

This product should be treated as an industrial 

waste when it is disposed.

Be sure to turn off power when not using it for 

a prolonged time.

  

The failure could result in injuries due 

to unintentional operation.

Introduction/ Checking the model

After unpacking

• Make sure that the model is what you have ordered.

• Check whether the product has been damaged or not during transportation.

If any deficiency should be found, 

contact the dealer store where you bought this product.

Checking the model of Amplifier, Motor and Gear head

This amplifier is designed for use in combination with a motor to be specified by us.

Check a name of series, rated output, voltage specifications  you wish to use

You must not use any other combinations than those listed below:

Standard

Shaft 

type

Voltage

Out put

Amplifier

Type

Applicable 

Motor

Applicable Gear head

GV series

Pinion shaft

Single phase

AC100 to 120 V

50 W MBEG5A1BCV

MBMU5AZAX

MX8G

B *

Reduction ratio: 3 to 180

90 W MBEG9A1BCV

MBMU9A1AZ

MZ9G

B *

MY9G

B *

Reduction ratio: 3 to 200

130 W MBEG1E1BCV

MBMU1E1AZ

Single phase/

3-phase

AC200 to 240 V

50 W MBEG5A5BCV

MBMU5AZAX

MX8G

B *

Reduction ratio: 3 to 180

90 W MBEG9A5BCV

MBMU9A2AZ

MZ9G

B *

MY9G

B *

Reduction ratio: 3 to 200

130 W MBEG1E5BCV

MBMU1E2AZ

Round shaft

Single phase

AC100 to 120 V

50 W MBEG5A1BCV

MBMU5AZAS

90 W MBEG9A1BCV

MBMU9A1AS

130 W MBEG1E1BCV

MBMU1E1AS

Single phase/

3-phase

AC200 to 240 V

50 W MBEG5A5BCV

MBMU5AZAS

90 W MBEG9A5BCV

MBMU9A2AS

130 W MBEG1E5BCV

MBMU1E2AS

GP

 series

Pinion shaft

Single phase

AC100 to 120 V

50 W MBEG5A1BCP

MBMU5AZAB

MB8G

BV *

Reduction ratio: 5 to 50

90 W MBEG9A1BCP

MBMU9A1AB

MB9G

BV *

Reduction ratio: 5 to 50

130 W MBEG1E1BCP

MBMU1E1AB

Single phase/

3-phase

AC200 to 240 V

50 W MBEG5A5BCP

MBMU5AZAB

MB8G

BV *

Reduction ratio: 5 to 50

90 W MBEG9A5BCP

MBMU9A2AB

MB9G

BV *

Reduction ratio: 5 to 50

130 W MBEG1E5BCP

MBMU1E2AB

* A figure representing reduction ration in 

e.g.) Part number of MX type gear head with reduction ratio 10 is MX8G10B.

Safety Precautions

Important

Do not frequently turn on and off the master 

power source.

  The failure could result in malfunction.

Do not place any obstacle that blocks ventilation 

around the brushless amplifier and the motor.

  The failure could result in burns or fire.

Summary of Contents for MBEG1E1BCP

Page 1: ...ep this manual with care after reading and read as necessary Be sure to give this Instruction manual to an end user Label of safety precaution is affixed to the product If you are the first user of this product please be sure to read the instruction Manual Overall from our Web Site Web address of Panasonic Corporation http industrial panasonic com ww i_e 25000 motor_fa_e motor_fa_e html This produ...

Page 2: ...urrent protection earth leakage breaker over temperature protecter and emergency stop device must be installed The failure could result in electric shocks injuries or fire Transportation wiring and checking must be performed with power source turned off and after making sure that there is no risk of electric shock The failure could result in electric shocks or injuries Do not subject the product t...

Page 3: ...ed or not during transportation If any deficiency should be found contact the dealer store where you bought this product Checking the model of Amplifier Motor and Gear head This amplifier is designed for use in combination with a motor to be specified by us Check a name of series rated output voltage specifications you wish to use You must not use any other combinations than those listed below Sta...

Page 4: ...ves great influence upon the life of brushless amplifier therefore choose a place in conformance with the conditions below 1 Indoors where the motor is not subjected to rain water and direct sun beam 2 Do not use the motor in corrosive atmosphere such as hydrogen sulfide sulfurous acid chlorine ammonia sulfur gas chloride gas sulfide acid alkali and salt in the atmosphere of combustible gas or in ...

Page 5: ...orming to voltage specification When you use single phase connect the main power between L1 and L2 terminals 8 L2 10 L1 1 2 4 7 9 NC Do not connect anything to NC Connector for control signals I O GV series Connector on amplifier side Parts No S10B PASK 2 J S TMfg Co Ltd or equivalent mating connector Representative Housing PAP 10V S Terminal SPHD 001T P0 5 or SPHD 002T P0 5 Terminal number Termin...

Page 6: ... 4 SIN 5 RS485 for connect RS485 6 RS485 for connest RS485 7 GND power supply GNG for Digital key pad 8 SCK Interface for digital key pad Maintenance inspections Routine maintenance and inspection are essential for proper and satisfactory operation of the motor Maintenance Inspection item Maintenance Check item Inspection procedure Condition Input voltage Voltmeter Must be within 10 of rating Inpu...

Page 7: ...this fact Brushless Amplifier Conformance to EC directive and UL standard Conformance to EC directive and UL standard Configuration of peripheral equipment Power supply 100 V system Single phase 100 V to 120 V 10 50 60 Hz 200 V system Single phase 200 V to 240 V 10 50 60 Hz Use the equipment under the environment of overvoltage category II specified by IEC60664 1 In order to obtain overvoltage cat...

Page 8: ... V P 1 Can be set by using the optional Digital key pad DV0P3510 sold separately or PANATERM for BL or through communication over RS485 2 The mark V is applied to the GV series P is applied to the GP series Cautions for Proper Use Cautions for Proper Use Practical considerations for exporting the product or assembly containing the product When the end user of the product or end use of the product ...

Page 9: ...can be downloaded from the following web site http industrial panasonic com ww i_e 25000 motor_fa_e motor_fa_e html Pursuant to at the directive 2004 108 EC article 9 2 Panasonic Testing Centre Panasonic Marketing Europe GmbH Winsbergring 15 22525 Hamburg F R Germany 7 1 1 Morofuku Daito Osaka 574 0044 Japan Phone 81 72 871 1212 For your records The model number and serial number of this product c...

Reviews: