No.SX-DSV01676
- 42 -
R2
Motor Company, Matsushita Electric Industrial Co., Ltd.
12-2 Configuration of peripheral equipments
12-2-1 Setup environment
Use the servo drive in environment of Pollution Degree 2 or 1 prescribed in IEC 60664-1. (E.g. Install inside of
the control box of IP54)
Power
supply
Circuit
breaker
Surge
absorber
Noise filter
Noise filter for
signal line
Insulated power
supply for interface
Controller
Servo
driver
Noise filter for
signal line
Servo
motor
M
CN-
X4
CN-
X5
Protective earth (PE)
L1
L2
L3
L1C(r)
L2C(t)
U
V
W
Control box
RE
12-2-2 Power supply
100V type: Single phase 100V to 115V 50/60Hz
200V type: (A to D-frame) Single/3-phase 200V to 240V 50/60Hz
200V type: (E and F-frame) 3-phase 200V to 230V 50/60Hz
(1) Use under environment of over-voltage category-II prescribed in IEC 60664-1.
(2) Use an interface power supply of DC12 to 24V, insulated type, which conforms to CE marking or
EN Standard (EN60950).
12-2-3 Circuit breaker
Connect a circuit breaker which conforms to IEC Standard and is UL recognized (UL Listed and
Marked) between the power supply and the noise filter without fail.
+10%
-15%
+10%
-15%
+10%
-15%
UL
Phone: 800.894.0412 - Fax: 888.723.4773 - Web: www.clrwtr.com - Email: [email protected]