6.2.2.5.  Installation of the Wave Washer

1. Install the Wave Washer.

6.2.2.6.   Installation of the Zoom Ring Unit,

the Ring Mount Base Unit and
the Zoom Drive Pin

1. Install the Zoom Ring Unit to Ring Mount Base Unit.

 None specified

 Torque

 8.0 ± 1.0 N 

cm

2. Install the Ring Mount Base Unit.

3. Tighten 3 screws (J) by using the torque driver

with specified torque.

4. Install the Zoom Drive Pin.
5. Tighten screw (H) by using the torque driver

with specified torque.

 Torque

 7.0 ± 1.0 N 

cm

 Screw Order

Zoom Ring Unit

Screw (H)

Screw (H)

Screw (J) 

3

Screw (J)

13

Summary of Contents for Lumix H-ES12060

Page 1: ...ximum aperture F2 8 Wide to F4 0 Tele Specifications INTERCHANGEABLE LENS FOR DIGITAL CAMERA LUMIX DG VARIO ELMARIT 12 60 mm F2 8 4 0 ASPH POWER O I S Focal length f 12 mm to 60 mm ⓒ Panasonic Corporation 2018 Unauthorized copying and distribution is a violation of law F22 Lens construction 14 elements in 12 groups 4 aspherical lenses 2 ED lenses In focus distance 0 20 m 0 66 feet to Wide 0 24 m 0...

Page 2: ...uctions 6 1 1 Assembly Flow Chart 6 1 2 Assembly Procedure 7 Adjustment 7 1 Matrix Chart for Replaced Part and Necessary Adjustment 7 2 Matrix Chart for Cleaning Portion and Necessary Adjustment 7 3 Flow Chart for Adjustment 7 4 Procedure for Adjustment 7 4 1 Service Fixture Tools 7 4 2 Pre setting 7 4 3 Projector General Purpose Camera Repair Lens setting 7 4 4 1st Lens Frame Adjustment 7 4 5 Ele...

Page 3: ... manual is written for Micro Four Thirds Lens H ES12060 As you may know lens hates dust soil sand fingerprint So that you have to repair disassembly assembly with close attention Or you have received customer complaint Use in the clean room clean box At least class 10000 This repair method isn t the exact same as factory production line So please obey description in this manual definitely Especial...

Page 4: ... different from the Exploded View Ref No 225 CAM BARREL UNIT 201 203 204 205 206 208 209 210 206 B214 B211 B213 B210 B214 B212 B215 B208 B209 B204 B205 225 226 227 228 B206 B207 B201 B203 B202 202 B221 B222 B223 224 221 222 223 222 1 225 For the repair part protection Dispose of it when replacing the part 2 ...

Page 5: ...MH1024Z 2ND LENS SHADING PLATE 1 225 4OU1HES12060Z CAM BARREL UNIT 1 B221 B223 VHD2096 SCREW 3 209 SXQ0649 L MOUNT UNIT 1 222 3OU1HES12060Z 2ND LENS FRAME UNIT 1 223 3DX4Z260Z 3RD LENS FRAME2 UNIT 1 224 5DE5Z260Z 5TH LENS FRAME UNIT 1 B215 B216 VHD2246 SCREW 2 B211 B213 VHD2299 SCREW 3 B214 VHD2298 SCREW 1 B206 B207 VHD2073 SCREW 2 B204 SHD0021 SCREW 1 L MOUNT CONTACT UNIT 1 207 RDE4Z260Z REAR FRA...

Page 6: ...clean level less than class 10 000 Federal Standard 209D Reference Camera Lens RFKZ0422 DMC GM5 H FS12032 Lens Cleaning Kit Torque Driver Torx Driver for Adjustment Blower VFK1900BK RFKZ0542 RFKZ0609 Only supplied 10 set box Glove Cloth Collimeter T3 type Lens Projector for Adjustment Lens Adaptor Projector Chart Lens Control Adaptor SUKZ000030 SUKZ000031 SUKZ000032 SUKZ000033 Rp Chart L size Rp C...

Page 7: ... the dirt on the Lens glass surface with Lens Cleaning Kit VFK1900BK if necessary Consult the instruction sheet which is included in the Lens Cleaning Kit in details 5 2 2 Cleaning procedures of inside surface of the Lens 1 When removing the each above unit it has to be proceed inside of satisfied clean level Less than class 10 000 Federal Standard 209D As for clean box refer to the 4 2 Clean Box ...

Page 8: ... Unit 3 Shading Frame 4 L Mount Unit 5 Dustproof Rubber Rear Frame Unit 6 L Mount Contact Unit Lens P C B Unit Rear Frame Earth Spring 13 5th Lens Frame Unit Come Barrel Unit 12 3rd Lens Frame2 Unit 10 1st Lens Holder Unit 11 2nd Lens Frame Unit 2nd Lens Shading Plate Attention If you do the disassemble procedure after this it requires the disassembly of No 1 and No 2 For adjustment after assembly...

Page 9: ...gently 6 1 2 2 Removal of the Filter Ring 6 1 2 4 Removal of the L Mount Unit 1 Remove 3 screws A and the Filter Ring 1 Remove screw C and 3 screws D 6 1 2 Disassembly Procedure 6 1 2 3 Removal of the Shading Frame 1 Remove 2 screws B and the Shading Frame 6 1 2 1 Removal of the Decoring Unit 1 The Decoring Unit is sticked on the Filter Ring 2 Put the sheet so that the lens glass is fullty covered...

Page 10: ... the Rear Frame Unit 6 1 2 6 Removal of the Lens P C B Unit and 3 Remove the L Mount Connect Unit from Lens P C B the L Mount Contact Unit 1 Disconnect the 4 Connectors of the Lens P C B 2 Disconnect the Connector of the Lens P C B and the Rear Frame Unit Connector Dustproof Rubber Screw E Screw E x 3 Connector Connector Connector Connector Screw F Screw F x 2 8 ...

Page 11: ...t 2 Remove 3 screws J and the Ring Mount Base Unit Spring 1 Remove screw G and the Rear Frame Earth Sprig 6 1 2 8 Removal of the Zoom Drive Pin the Ring Mount Base Unit and 1 Remove screw H and the Zoom Drive Pin Screw G Screw G SILVER Rear Frame Earth Spring Screw H Screw H Zoom Ring Unit Screw J x 3 Screw J 9 ...

Page 12: ...emoval of the 3rd Lens Frame2 Unit 1 Remove the 3rd Lens Frame2 Unit Shading Plate 6 1 2 9 Removal of the Wave Washer 3 Remove the 2nd Lens Shading Plate fixed to the 2nd 1 Remove the Wave Washer 6 1 2 10 Removal of the 1st Lens Holder Unit 1 Rotate the Cam Barrel clockwise when you watch it from back Remove the Cam Barrel while avoiding the 1st Lens Pin so as not to scratch the surface of the 2nd...

Page 13: ...ct Unit Lens P C B Unit 9 Rear Frame Unit Dustproof Rubber 4 1st Lens Holder2 Unit 5 Wave Washer 7 Rear Frame Earth Spring 6 Zoom Ring Unit Ring Mount Base Unit Zoom Drive Pin Lens Unit 12 Filter Ring 10 L Mount Unit 11 Shading Frame 13 Decoring Unit Attention If you made the assembly of the No 4 from No 1 it will requre adjustment before assembling the No 12 and No 13 11 ...

Page 14: ...allation of the 3nd Lens Frame2 Unit 1 Install the 3rd Lens Frame2 Unit after aligning point in the figure below 3 Install the 2nd Lens Frame Unit 4 Rotate the arrow point counterclockwise until it does not rotate when you watch it from back 6 2 2 4 Installation of the 1st Lens Holder Unit to the Cam Barrel 1 Align phase mark and rotate the Cam Barrel counterclockwise when you watch it from back I...

Page 15: ...l the Zoom Ring Unit to Ring Mount Base Unit None specified Torque 8 0 1 0 N cm 2 Install the Ring Mount Base Unit 3 Tighten 3 screws J by using the torque driver with specified torque 4 Install the Zoom Drive Pin 5 Tighten screw H by using the torque driver with specified torque Torque 7 0 1 0 N cm Screw Order Zoom Ring Unit Screw H Screw H Screw J x 3 Screw J 13 ...

Page 16: ... cm 1 Install the Rear Frame Earth Spring with specified torque 2 Tighten screw G by using the torque driver with specified torque 6 2 2 7 Installation of the Rear Frame Earth 2 Installation the Main P C B with the Mount Contact Unit 3 Tighten 2 screws F by using the torque driver Spring Torque 6 0 0 5 N cm Connector Screw G Screw G SILVER Rear Frame Earth Spring Screw F Screw F x 2 Connector Conn...

Page 17: ... 0 1 0 N cm Torque 7 0 1 0 N cm 2 Tighten 3 screws E in numerical order by using the torque driver with specified torque Screw Order Torque screw D 20 0 1 2 N cm 6 2 2 9 Installation of the Rear Frame Unit 6 2 2 10 Installation of the L Mount Unit and the Dustproof Rubber 1 Install the L Mount Unit Dustproof Rubber Screw E Screw E x 3 Connector Screw C Screw D Screw C Screw D x 3 15 ...

Page 18: ...r Ring by using the torque driver with specified torque Use new one do not use the one which is removed Double stick tape sticks to the Decoring Unit of the repair part Remove the old double stick tape from the Filter Ring 2 After installing the Decoring Unit use a soft cloth to press it into place Screw Order Torque 10 0 1 0 N cm 6 2 2 11 Installation of the Shading Frame 6 2 2 13 Installation of...

Page 19: ... and Necessary Adjustment The relation Cleaning portion and Necessary Adjustment is shown in the following table When concerned part is replaced be sure to achieve the necessary adjustment s Outside surface of the Lens CAM BARREL UNIT Cleaning Portion 1st Lens Frame Adjustment Necessary Adjustment Inside surface of the Lens Electrical Adjustment DECORING UNIT 1 Replaced Part 1st Lens Frame Adjustm...

Page 20: ... Remove glue on the 2 adjustment pins Repeat adjustment from 1st Lens Frame Adjustment Electrical Adjustment All item Electrical Adjustment Back Focus only 1st Lens Frame Adjustment Initial Second time Confirm RP Glue 1st Lens Frame Adjustment Pin Confirm RP Finish OK OK NG NG 1 Note 2 Note 18 ...

Page 21: ...Adaptor Extension cable for OIS control SUKZ000033 General Purpose Camera Body DMC GM5 series Battery Purchased locally Hand Miller Purchased locally RP Chart L Size SUKZ000034 RP Chart M Size SUKZ000035 Tripod Purchased locally PC Purchased locally SD Card Purchased locally Dark Room Keep measurement distance for at least 3m RP Chart L Size 600x800mm SUKZ000034 RP Chart M Size 300x400mm SUKZ00003...

Page 22: ...e mounting the Repair Lens Decring Unit Filter Ring are uninstalled Remove Lock Tight by alcohol on the Adjustment Pin 7 4 3 Projector General Purpose Camera Repair Lens setting 1 Turn on Lens Projector and Lens Chart to Wall 2 Turn on General Purpose Camera and activate OIS make sure OIS move to centre of optical axis 3 Keep 3m distance between Lens Projector and Chart on the Wall 4 Place Hand Mi...

Page 23: ...tion Transfer Frequency is within spec Refer to spec WIDE Observation point Centre and four corners Angle of view 0 7 and four corners on the Mark 4 circle 5 If not within spec repeat the adjustment from the above step 1 If not within spec more than five times implement the re assembly and re exchange of replacement parts Adjustment Pin 1st Lens Frame Adjustment Pin Adjustment Pin 1st Lens Frame T...

Page 24: ...tment distance between the camera and RP Chart so that picture size and horizontal level in TELE RP Chart M Size and WIDE RP Chart L Size is full display camera LCD 5 Focus on centre in the open aperture state TELE 4 0 WIDE 2 8 take photo by self timer mode as camera shake does not occur 6 As the Shutter Speed of photo taken will be 1 30 1 125 adjust the shooting enviroment Brightness The Shutter ...

Page 25: ...RP Chart L Size 600x800mm SUKZ000034 RP Chart M Size 300x400mm SUKZ000035 23 ...

Page 26: ... TELE RP Chart M Size and WIDE RP Chart L Size is full display camera LCD 5 Focus on centre in the open aperture state TELE 4 0 WIDE 2 8 take photo by self timer mode as camera shake does not occur 6 As the Shutter Speed of photo taken will be 1 30 1 125 adjust the shooting enviroment Brightness The Shutter Speed is confirmed in the Exif information 7 Shooting photos to display at an equal magnifi...

Page 27: ...8 Revision History 1 0 2018 06 18 Final Version Issue Ver Date History 2018 04 09 Tentative Issue 25 ...

Reviews:

Related manuals for Lumix H-ES12060