39
9.4.
Lens Disassembly Procedure
Precaution:
1. Do not remove the C-MOS when disassembling or re-
assembling the lens in order to maintain it clean.
When remove it, refer to item "8.6".
2. Keep dust or dirt away from the lens.
3. To remove dirt or dust from the lens, blow with dry air.
4. Do not touch the lens surface.
5. Use lens cleaning KIT (BK)(VFK1900BK).
6. Apply grease (RFKZ0472) as shown on "THE APPLICA-
TION OF GREASE METHOD" in the figure.
7. Apply a light coat of grease using an object similar to a
toothpick.
9.4.1.
Removal of the Zoom Motor Unit
and Master Flange Unit
1. Unscrew the 2 screws (A).
2. Remove the Zoom Motor Unit.
3. Unscrew the 4 screws (B).
4. Remove the Connector (24p).
5. Remove the Connector (10p).
6. Remove the Master Flange Unit.