7.2.
When Replacing the Main PCB
After replacing the MAIN PCB, be sure to achieve adjustment.
The adjustment instruction is available at “software download” on the “Support Information from NWBG/VDBG-PAVC” web-site in
“TSN system”, together with Maintenance software.
7.3.
Service Position
This Service Position is used for checking and replacing parts. Use the following Extension cables for servicing.
Table S1 Extension Cable List
CAUTION-1. (When servicing FLASH TOP PCB)
1. Be sure to discharge the capacitor on FLASH TOP PCB.
Refer to “HOW TO DISCHARGE THE CAPACITOR ON FLASH TOP PCB”.
The capacitor voltage is not lowered soon even if the AC Cord is unplugged or the battery is removed.
2. Be careful of the high voltage circuit on FLASH TOP PCB.
3. DO NOT allow other parts to touch the high voltage circuit on FLASH TOP PCB.
No.
Parts No.
Connection
Form
1
VFK1951
FP9002 (MAIN) - LENS UNIT
39PIN 0.3 FFC
2
VFK1951
FP9001 (MAIN) - CCD UNIT
39PIN 0.3 FFC
3
VFK1974
FP9004 (MAIN) - LCD UNIT
4PIN 0.3 FFC
4
RFKZ0354
FP9103 (MAIN) - LCD UNIT
37PIN 0.5 FFC
5
VFK1906
PP9001 (MAIN) - PS8001 (FLASH TOP)
20PIN B to B