<PRO6> (Note 7)
<PRO5>
Normal mode
Code setting
CUSTOM setting
Reset setting
Display adjustment
setting
Window comparator
mode
(Except sensing output 2)
Self-diagnosis
output mode
(Except sensing output 1)
Answer back output
mode (Note 8)
(Except sensing output 1)
Response time
setting
Hysteresis setting
Blink
OFF
Emission halt
setting
Data bank loading
setting
Target setting
(Note 6)
5LVLQJGLႇHUHQWLDO
mode
7UDLOLQJGLႇHUHQWLDO
mode
Hysteresis
mode
Forced OFF
output mode
Forced ON
output mode
Light-receiving
sensitivity setting
Code setting
Blinks 3 times
&RQ¿UP
SET
SET
SET
SET
SET
SET
+, -
+, -
+, -
+, -
+, -
+, -
+, -
+, -
+, -
+, -
SET
+, -
+, -
+, -
+, -
+, -
+, -
+, -
+, -
+, -
+, -
+, -
<When selecting target setting>
Target setting
Display adjustment
setting
&RQ¿UP
&RQ¿UP
Changeable incident
light intensity in + or -
Incident light
intensity
0
&RQ¿UP
SET
SET
SET
SET
SET
+, -
Notes 6) Target setting of display adjust setting depends on the re-
sponse time as table below.
Response time
Target setting
“
”, “
”, “
”
From -1,999 to 4,000
“
”, “
”, “
”
From -1,999 to 9,999
Automatic
<RUN mode>
Only displayed in
/6Ƒ&
+, -
+, -
Notes: 7) Set the sensing output setting after input / output setting for
/6Ƒ
.
8) After external input, the time given until an answer back output is as follows. How-
HYHULQFDVHWLPHURIWKHVHQVLQJRXWSXWLVYDOLGWKHRXWSXWWLPHLVGLႇHUHQWIURP
the following table.
Input time
2 point teaching
Limit teaching
Full auto teaching
After 20ms from the input end, the answer back output is
read out when result of the teaching is “
”.
Display adjust
After 20ms from the input end, the answer back output is
read out.
Data bank loading
Data bank saving
After 520ms from rising of last input pulse, the answer back
output (pulse) of the number of channel in the data bank is
read out.
9) Incident light intensity depends on the response time as table below.
Response time
Incident light intensity
“
”, “
”, “
”
Max. 4,000
“
”, “
”, “
”
Max. 9,999
+, -
By pressing down MODE key long time,
sensing output 1 or 2 can be changed to
another.
<Window comparator mode or Hysteresis mode>
(The following diagram shows in selecting the window comparator mode.)
Shift amount setting
(Displayed in percentage)
Shift amount setting
(Note 9)
SET
SET
SET
SET
+, -
+, -
+, -
<PRO7>
<PRO1>
Logic operation
setting
Setting of threshold
value tracking
Between adjacent
DPSOL¿HU
Setting of threshold
tracking cycle
Sensing output
setting
Algorithm setting
(Note 10)
Storage cycle
setting
Between external
input
Between sens-
ing output 1 and
sensing output 2
and
1 sec.
ON
Auto teaching
1 time
and
and
or
or
or
Invalid
OFF
OFF
Limit teaching
OFF
Invalid
Invalid
xor
xor
xor
SET
SET
SET
SET
SET
SET
SET
SET
SET
SET
+, -
+, -
+, -
+, -
+, -
+, -
+, -
+, -
+, -
+, -
+, -
+, -
+, -
+, -
+, -
+, -
+, -
+, -
+, -
+, -
+, -
+, -
+, -
+, -
+, -
Notes: 10) In case setting to “
”, conduct the limit teaching for
the changed incident light intensity.
Shift direction of the threshold differs depending on the
combination of the sensing output status and the sensing
output operation.
Sensing output status
Sensing output operation
Shift direction
Sensing output ON
Light-ON
-
Sensing output ON
Dark-ON
+
Sensing output OFF
Light-ON
+
Sensing output OFF
Dark-ON
-
+, -