47
2-3-2 Installation method
• Install the head on a plate with a thickness of 10 mm to 15 mm which is made of aluminum or other material with
radiation performance equivalent to that of aluminum.
• For details of installation, refer to “1-4-1 Head” (P.29).
• Fix the head in the following conditions.
Head type
Fixing surface
Fixing screw
Screw insert length
Tightening torque
Standard head
Bottom
M6 screws at 6
positions
7 mm to 10 mm
3.0N
・
m
Tower head
Rear
7 mm to 10 mm
Bottom
(laser emission port side)
5 mm to 7 mm
A
B
M6 screw
Laser marker head
A : Inserting length of the screw (See above table for the length.)
B : Washer thi stand thick
When installing the head, refer to the above table and fix the six M6 screw holes.
M6 screw
M6 screw
M6 screw
Tower head model
Standard head model
ワㄐㄕㄊㄆ
• Do not insert any screw of length exceeding the specification. Otherwise, the failure of the product may be caused.
ME-LPRH-SM-3