235
ERROR
CODE
Description
Measures *1
E781
• Model number mismatch.
• Incorrect connection of signal cable or unit
power cable.
• Make sure the connected laser marker
components have the correct model numbers.
• For LP-GS series, it is recommended to connect
the head and controller that have the same model
numbers. If you combine the different models, the
model number of the laser head is applied to the
laser marking system.
• Check the connection of the cable and various
signal lines, and then restart the laser marker.
GSD file version error.
Download the GSD file (XML file) compatible with the
version number of the laser marker used and perform
updating. If the GSD file version is incorrect, settings
by your PLC cannot be imported to the laser marking
system correctly.
E783 *5, *6
The version of the expansion board is incorrect.
Update the firmware in the controller and expansion
board. The software for updating the LP-RH/LP-
ZV series, Laser Marker Firmware Updater, can be
downloaded from the following website:
https://www3.panasonic.biz/ac/e/fasys/software_info/
lasermarker/tol_lp-zv_firm.jsp
*1 : If the error persists after restart of the laser marker, contact our sales office or representatives.
*2 : Error that may occur for LP-GS series only.
*3 : Error that may occur for LP-RC series only.
*4 : Error that may occur for LP-RF, LP-RV and LP-ZV series only.
*5 : Error that may occur for LP-ZV series only.
*6 : Error that may occur for LP-RH series only.
ME-LPRH-SM-3
Summary of Contents for LP-RH Series
Page 19: ...1 Product Overview ME LPRH SM 3...
Page 42: ...2 Laser Marker Installation ME LPRH SM 3...
Page 68: ...3 Operation Method ME LPRH SM 3...
Page 90: ...4 External Control Using I O ME LPRH SM 3...
Page 138: ...5 External Control by Communication Commands ME LPRH SM 3...
Page 147: ...6 Link Control with External Devices ME LPRH SM 3...
Page 172: ...7 Maintenance ME LPRH SM 3...
Page 201: ...Troubleshooting ME LPRH SM 3...
Page 236: ...Index ME LPRH SM 3...
Page 239: ......