224
ERROR
CODE
Description
Measures *1
E505 - E509
E550 - E560
E572
Safety functions (INTERLOCK, LASER STOP,
etc.) were activated during marking preparation.
• Reset the alarm for LASER STOP IN or
INTERLOCK of the I/O terminal block or Stop
laser button of Laser Marker NAVI smart
software.
• Check if the signal lines are affected by noise.
E520 - E522
E570
File data or system data were not saved
successfully, because the laser marker was
turned off while saving data.
Unable to read the file data.
• Overwrite the data again to the selected file
number.
• Do not turn off the laser marker while saving
the settings.
E530 - E542
E571
• Restore the backup file saved before to the
laser marker.
• Do not turn off the laser marker while saving
the settings.
*1 : If the error persists after restart of the laser marker, contact our sales office or representatives.
*2 : Error that may occur for LP-GS series only.
*3 : Error that may occur for LP-RC series only.
*4 : Error that may occur for LP-RF, LP-RV and LP-ZV series only.
*5 : Error that may occur for LP-ZV series only.
*6 : Error that may occur for LP-RH series only.
ME-LPRH-SM-3
Summary of Contents for LP-RH Series
Page 19: ...1 Product Overview ME LPRH SM 3...
Page 42: ...2 Laser Marker Installation ME LPRH SM 3...
Page 68: ...3 Operation Method ME LPRH SM 3...
Page 90: ...4 External Control Using I O ME LPRH SM 3...
Page 138: ...5 External Control by Communication Commands ME LPRH SM 3...
Page 147: ...6 Link Control with External Devices ME LPRH SM 3...
Page 172: ...7 Maintenance ME LPRH SM 3...
Page 201: ...Troubleshooting ME LPRH SM 3...
Page 236: ...Index ME LPRH SM 3...
Page 239: ......