4-5 Connecting I/O Terminal Block
WARNING
• Make sure that the power is turned OFF at wiring.
4-5-1 Factory default wiring
The following terminals are connected by jumper wires at the factory default. Remove these jumper wires when you
connect them to an external device.
INTERLOCK 2(-)
INTERLOCK 2(+)
LASER STOP IN
LASER STOP IN
24V OUT
0V OUT
OUT COM. 1
IN COM. 1
OUT COM. 1
INTERLOCK 1(-)
INTERLOCK 1(+)
X1
X2
X3
X4
X5
X6
X7
X8
X9
X10
X11
X12
X13
X14
X15
X16
X17
X18
X19
X20
Y1
Y2
Y3
Y4
Y5
Y6
Y7
Y8
Y9
Y10
Y11
Y12
Y13
Y14
Y15
Y16
Y17
Y18
Y19
Y20
I/O terminal block
REMOTE INTERLOCK IN
Short-circuited
Short-circuited
Short-circuited
Short-circuited
Short-circuited
ワㄐㄕㄊㄆ
• Do not short-circuit 24V OUT (X1, Y3) and 0V OUT (X3, Y1). Also, do not short-circuit IN COM. 1 (X2) and OUT COM.1
(Y2, X12). Starting the laser marker with these terminals short-circuited will cause the laser marker to malfunction.
ンㄆㄇㄆㄓㄆㄏㄆ
• To enable the laser radiation, connect IN COM. 1 (X2) and OUT COM. 1 (Y2) respectively to the internal of external
power supply. Refer to “4-5-2 Connecting common terminals” (P.113).
• The following terminals of the I/O terminal block are the common terminals connected internally.
• X1 and Y3: 24V OUT
• X3 and Y1: 0V OUT
• Y2 and X12: OUT COM. 1
ME-LPRH-SM-3
Summary of Contents for LP-RH Series
Page 19: ...1 Product Overview ME LPRH SM 3...
Page 42: ...2 Laser Marker Installation ME LPRH SM 3...
Page 68: ...3 Operation Method ME LPRH SM 3...
Page 90: ...4 External Control Using I O ME LPRH SM 3...
Page 138: ...5 External Control by Communication Commands ME LPRH SM 3...
Page 147: ...6 Link Control with External Devices ME LPRH SM 3...
Page 172: ...7 Maintenance ME LPRH SM 3...
Page 201: ...Troubleshooting ME LPRH SM 3...
Page 236: ...Index ME LPRH SM 3...
Page 239: ......