39
3-1-2 Command description
Reference
•
The laser marker sends a response data after setting/readout command is transmitted. Refer to “2-5 Communication
■
Command reception permission: MKM
Controls the reception permission (reception mode ON/OFF) for setting and readout of communication commands.
Setting / Readout data of command reception mode
STX
MKM
Sub
command
[Command reception mode]
1-byte
(Check sum)
Delimiter
Sub command is “S” at the time of setting and “A” for response data at the time of readout.
Readout request of command reception mode
STX
MKM
R
(Check sum)
Delimiter
Name
Data length
[byte]
Description
Remarks
Command
reception mode
1
“0”: Reception mode ON
Start command reception in
the marking ready OFF status
“1”: Reception mode OFF
Finish command reception
and resume the marking ready
ON status
In the shutter open or marking ready ON status,
set “reception mode ON” when transmitting the
communication command including an action
to update the laser marker data. To resume the
ready ON status after command transmission,
set “reception mode OFF”.
Reference
•
For details on command reception permission, refer to “2-2 Command Reception Condition” (P.22).
•
Send MKM command with the shutter opened state. When DIP switch No. 2 is ON and the shutter is closed, the shutter
opens at the timing of “reception mode OFF” is set.
■
Laser pumping: LSR
Controls the laser pumping ON/OFF.
Setting / Readout data of laser pumping
STX
LSR
Sub
command
[Laser pumping]
1-byte
(Check sum)
Delimiter
Sub command is “S” at the time of setting and “A” for response data at the time of readout.
Readout request of laser pumping state
STX
LSR
R
(Check sum)
Delimiter
Name
Data length
[byte]
Description
Remarks
Laser pumping
1
“0”: Laser pumping OFF
“1”: Laser pumping ON
Reference
•
Control of laser pumping by this command is unavailable when the No. 2 DIP switch on the back surface of controller is
turned to OFF.
•
It takes about 20 seconds for LP-Mxxx / LP-Sxxx / LP-Zxxx and about 15 seconds for LP-SxxxW from turning ON the
laser pumping to the completion of pumping.
ME-LPMSZ-SR-9
Summary of Contents for LP-M Series
Page 8: ...1 Before External Control ME LPMSZ SR 9...
Page 16: ...2 Basics of Serial Communication RS 232 Ethernet ME LPMSZ SR 9...
Page 34: ...3 Communication Command and Function ME LPMSZ SR 9...
Page 165: ...Troubleshooting ME LPMSZ SR 9...
Page 186: ...Character Code Table ME LPMSZ SR 9...
Page 199: ...Index ME LPMSZ SR 9...
Page 202: ...202 MEMO No 9000 0063 59V ME LPMSZ SR 9...
Page 203: ...No 9000 0063 59V...
Page 204: ...Panasonic Industrial Devices SUNX Co Ltd 2013 2019 March 2019 9000 0063 59V...