Battery System User Manual for Panasonic LJ-SK84A
Grid Tied PV System
–
User Manual
Version 1.0 © solarcity 2016 UM-1059-PV-1.0
7
6.6 Stand-alone mode
The battery system is equipped with an emergency stand-alone power outlet. This outlet is limited to a maximum load
of 2000 Watts and can be used to supply power to certain devices in case of a power cut.
CAUTION! Do not attempt to connect devices that, in total, require more power than 2000 W. If you exceed
2000 W the integrated battery protection device will trip and disconnect the internal battery packs. As a
consequence the system will not work. A qualified electrician will need to service the battery so it can be
turned on again.
As a precaution, only connect devices to the Stand-alone power outlet that have significantly lower power
consumption than 2000 W.
Suitable Devices
Unsuitable Devices
Cell phone chargers, laptop chargers
Vacuum cleaner
Router, modem
Microwave oven
LED TV
Any water pumps
LED lighting or halogen lighting
Kettle
Small HiFi system or radio
Hairdryer
6.6.1 How to activate and deactivate the stand-alone power outlet
The Stand-alone mode can be set to be activated automatically or manually. Please refer to section 6.7.3 for further
details. This section explains how to use the Stand-alone mode manually.
If a power cut occurs, the GRID indicator light will be orange and the display will show PF (for Power Failure) followed
by 0.0. You might also see some error codes such as E020 for low grid voltage.
To activate the emergency stand-alone power supply during a power failure, press the ON/OFF button for 1 second
until you see PF followed by 3 hyphens. Press the ON/OFF button again for 1 second to activate the Stand-alone mode.