background image

Battery System User Manual for Panasonic LJ-SK84A 

 

 

 

Grid Tied PV System 

 User Manual

 

Version 1.0 © solarcity 2016 UM-1059-PV-1.0

 

 

The  Panasonic  battery  is  a  stand-alone  system  and  will  be  fully  set  up  and  programmed  at  the  time  of  installation. 
There are, however, a number of functions that you can access, such as the emergency  Stand-alone mode, which is 
explained in section 6.6. The display shows basic information such as the state of charge, mode of operation, current 
charge or discharge rate and the time and date.  
 
The battery will be set to the most suitable and economic mode for your specific purposes. In most cases this will be 
the 

maximise self-consumption

 mode, indicated by 

SELF

 on the battery display. 

 
The control panel is in the centre, at the top of the battery system. It consists of 4 LED indicator lights, a display and 4 
buttons.  

 

 

 

 

The LED indicator lights are useful to check the current state of the battery system. Under normal conditions: 
 

 

GRID shows green - the battery is connected to the grid 

 

MODE shows green 

 the battery is operating in Grid mode (changes to orange in Stand-alone mode) 

 

BATTERY shows green - the battery is supplying energy to your home 

 

BATTERY shows orange - the battery is charging

 

 

 

 

 

 

 
 

The buttons on the right hand side of the control panel can be used to show further information about 
the current battery state, to change settings, or to confirm or cancel settings.

 

 

Summary of Contents for LJ-SK56A

Page 1: ...Battery System User Manual for Panasonic LJ SK56A BATTERY SYSTEM USER MANUAL FOR PANASONIC LJ SK56A ...

Page 2: ...t works 4 6 0 THE STORAGE BATTERY SYSTEM 5 6 1 Battery enclosure 5 6 2 Network adapter 5 6 3 Monitoring 5 6 4 Server adaptive mode 5 6 5 The battery control and display panel 5 6 6 Stand alone mode 7 6 6 1 How to activate and deactivate the stand alone power outlet 7 6 7 User settings 8 6 7 1 Lower discharge limit 9 6 7 2 Child lock 10 6 7 3 Stand alone operation start setting 10 6 8 Help 11 7 0 M...

Page 3: ...ed in accordance with AS NZS wiring standards by a registered electrician Any unauthorised altering of the wiring presents the risk of high voltages being exposed and the risk of death or serious injury to users of the property where the system is installed 3 0 ACTIONS IN CASE OF SYSTEM FAILURE In an emergency you can shut down the battery system if it is safe to do so as outlined in Section 4 0 F...

Page 4: ... charge If the system is fully charged and the supply from the solar system still exceeds your energy demand electricity will be exported to the grid This energy is metered and is purchased by your electricity retailer at an agreed tariff When the solar system is not generating enough to supply the load requirements of your home and the batteries are charged the battery system supplies electricity...

Page 5: ...section 6 4 below 6 3 Monitoring The battery system can be monitored through a smartphone application that is available for Android and iOS devices You can download the Panasonic monitor application from the Apple app store or the Google Play store For iOS the application can be found here https itunes apple com nz app panasonic home storage battery id1121486441 mt 8 For Android the application ca...

Page 6: ...ic purposes In most cases this will be the maximise self consumption mode indicated by SELF on the battery display The control panel is in the centre at the top of the battery system It consists of 4 LED indicator lights a display and 4 buttons The LED indicator lights are useful to check the current state of the battery system Under normal conditions GRID shows green the battery is connected to t...

Page 7: ... that have significantly lower power consumption than 2000 W Suitable Devices Unsuitable Devices Cell phone chargers laptop chargers Vacuum cleaner Router modem Microwave oven LED TV Any water pumps LED lighting or halogen lighting Kettle Small HiFi system or radio Hairdryer 6 6 1 How to activate and deactivate the stand alone power outlet The Stand alone mode can be set to be activated automatica...

Page 8: ...rge limit can be set which will guarantee that the battery will always have a minimum remaining level of electricity stored in case of a power cut However this will also reduce the available capacity for day to day power cycling If you experience frequent power cuts in your area you can set the lower discharge limit to an appropriate level Example If you want to ensure that you are able to charge ...

Page 9: ...er You don t need to change this setting When finished with the User Setting menu you will need to start the battery again Press ON OFF repeatedly to return to the initial display showing 5 dashes Press the ON OFF button for 1 second to start the battery The hyphens will disappear and the display will show a number between 0 0kW and 2 0kW 6 7 1 Lower discharge limit solarcity recommends the lower ...

Page 10: ...usly to start or stop the battery 6 7 3 Stand alone operation start setting The battery system can be set to switch to stand alone operation automatically if a power cut occurs However it will not switch back to normal operation automatically when the power is back You ll have to activate normal operation manually after using the stand alone function As a safety measure you should ensure that the ...

Page 11: ...long operating life The system MUST be shut down to perform the cleaning steps below Do not clean the battery by sprinkling water over it or using a hose Do not use any materials that could scratch the surface We recommend using a soft microfiber cloth Do not use any volatile or abrasive substances to clean the surface These may damage the special coating that protects the battery against rusting ...

Page 12: ...ions improve E020 Low grid voltage Normal operation will resume once conditions improve E030 AC over frequency Normal operation will resume once conditions improve E040 AC under frequency Normal operation will resume once conditions improve E060 Abnormal grid Normal operation will resume once conditions improve E070 Instantaneous over voltage Normal operation will resume once conditions improve E0...