background image

2

•  This manual describes how to operate the Heatpump system 

  between indoor and outdoor units only.

•  Other operation such as water tank, radiator, external thermo controller 

and under

fl

 oor system, please refer to respective manufacturer 

operation manuals.

SAFETY PRECAUTIONS

TABLE OF CONTENTS

TABLE OF CONTENTS

SAFETY PRECAUTIONS

2~3

CONTROL PANEL

4~7

INDOOR UNIT

8

TROUBLESHOOTING

9

INFORMATION

34~35

NOTE

NOTE

The illustrations in this manual are for 

explanation purposes only and may 

differ from the actual unit. It is subjected 

to change without notice for future 

improvement.

OPERATION CONDITION

OPERATION CONDITION

Water outlet

Temperature (°C)

Indoor

HEATING

Max.

55

Min.

25

Ambient

Temperature (°C)

Outdoor

HEATING

Max.

35

Min.

-20

NOTICE :  When the outdoor temperature 

is out of the above temperature 

range, the heating capacity will 

drop signi

fi

 cantly and outdoor 

unit might stop for protection 

control.

To prevent personal injury, injury to others, or property damage, please 

comply with the following.

Incorrect operation due to failure to follow instructions below may cause 

harm or damage, the seriousness of which is classi

fi

 ed as below:

  

WARNING

WARNING

This sign warns of death or serious injury.

  

CAUTION

CAUTION

 

This sign warns of injury or damage to 
property.

The instructions to be followed are classi

fi

 ed by the following symbols:

This symbol denotes an action that is 
PROHIBITED.

 

 

 

These symbols denote an action that 
is COMPULSORY.

 

WARNING

WARNING

INDOOR UNIT AND OUTDOOR UNIT

This appliance is not intended for use by persons (including 

children) with reduced physical, sensory or mental 

capabilities, or lack of experience and knowledge, unless 

they have been given supervision or instruction concerning 

use of the appliance by a person responsible for their safety. 

Children should be supervised to ensure that they do not 

play with the appliance.
Please consult authorized dealer or specialist to repair, 

install, remove and reinstall the unit. Improper installation 

and handling will cause leakage, electric shock or 

fi

 re.

Do not install the unit in a potentially explosive or 

fl

 ammable 

atmosphere. Failure to do so could result in 

fi

 re.

Do not insert your 

fi

 ngers or other objects into the 

indoor or outdoor unit, rotating parts may cause 

injury.
Do not touch the outdoor unit during lightning, it may cause 

electric shock.
Do not attempt to repair the unit by yourself. Otherwise, 

it may cause injury if it is mishandling.
Do not install the indoor unit at outdoor. This is designed for 

indoor installation only.

Summary of Contents for LIAC12IM6

Page 1: ...llation fournies 10 17 10 17 ESPAÑOL Antes de utilizar la unidad sírvase leer atentamente estas instrucciones de funcionamiento y conservarlas como futuro elemento de consulta Antes de operar la unidad asegúrese de que la instalación haya sido realizada correctamente por un instalador autorizado siguiendo de forma correcta y precisa las instrucciones de instalación dadas 18 25 18 25 DEUTSCH Bevor ...

Page 2: ...his sign warns of death or serious injury CAUTION CAUTION This sign warns of injury or damage to property The instructions to be followed are classified by the following symbols This symbol denotes an action that is PROHIBITED These symbols denote an action that is COMPULSORY WARNING WARNING INDOOR UNIT AND OUTDOOR UNIT This appliance is not intended for use by persons including children with redu...

Page 3: ...zene thinner or scouring powder Do not inspect or service the control panel by not inspect or service the control panel by yourself Please consult authorized dealer yourself Please consult authorized dealer Otherwise it may cause injury if mishandling WARNING WARNING POWER SUPPLY Do not use modified cord joint cord extension cord or unspecified cord to prevent overheating and fire Do not share the...

Page 4: ... Actual Operation OFF ON Indicator 6 System Setting Mode Buttons 19 System Setting Mode OFF ON Indicator 7 Timer Setting Group Buttons 20 System Status Check Mode OFF ON Indicator 8 Force Heater Mode Button 21 System Pumpdown Mode OFF ON Indicator 9 System Pumpdown Mode Button 22 Timer Clock Setting Display 10 System Status Check Mode Buttons 23 External Thermo Controller Connected Display 11 Erro...

Page 5: ...t your desired day and time 5 Press SET to confirm Function Operation Mode Actual Operation Description External Thermo Controller YES NO To set external thermo controller connection TANK Tank Connection YES NO To set tank connection HEAT Heating Priority YES NO To choose the heat pump only use for Heating side during HEAT TANK mode HEAT Heating Heat up Interval Set To set timer for Heating during...

Page 6: ... ON STATUS mode cannot be activated when the SETTING indicator is ON It is strongly recommended to contact the nearest authorized dealer to change the water temperature range Using the control panel could set the temperature range for water outlet temperature and outdoor ambient temperature SYSTEM SETTING MODE SET SELECT CANCEL SETTING TIMER OUTDOOR HEAT SETTING STATUS PUMPDW BOOSTER QUIET TANK WA...

Page 7: ...t steps 4 to 7 to set programs 2 to 6 During timer setup if no button is pressed within 30 seconds or if the SET button is pressed the setting at that moment is confirmed and timer setup is ended Add Modify timer Repeat the steps above Disable timer Press TIMER then press CANCEL Enable timer Press TIMER then press SET Check timer 1 Press TIMER 2 Press or until your desired day is shown press SELEC...

Page 8: ...nit gently with a soft dry cloth EXTERNAL FILTER Please clean the external filter at least once a year Fail to do so might cause filter clogged consequent system breakdown Please consult authorized dealer OUTDOOR UNIT Do not obstruct the air inlet and air outlet vents it may cause low performance or breakdown Please remove obstacles to assure the ventilation During winter please clean and remove t...

Page 9: ...s low it may be difficult to get warm System cannot get warm instantly Due to the nature of the heatpump system it may take some time to heat up the water if the unit is operated from cold start Operation starts after power resumes Unit is operates under auto restart function Check the following before calling for servicing Check the following before calling for servicing SYMPTOM SYMPTOM CHECK CHE...

Page 10: ...s Apposé sur le produit lui même sur son emballage ou figurant dans la documentation qui l accompagne ce pictogramme indique que les piles et appareils électriques et électroniques usagés doivent être séparés des ordures ménagères Afin de permettre le traitement la valorisation et le recyclage adéquats des piles et des appareils usagés veuillez les porter à l un des points de collecte prévus confo...

Page 11: ...istribuidor y consulte por el método correcto de eliminación Benutzerinformation zur Sammlung und Entsorgung von veralteten Geräten Diese Symbole auf den Produkten Verpackungen und oder Begleitdokumenten bedeuten dass benutzte elektrische und elektronische Produkte und Batterien nicht in den allgemeinen Hausmüll gegeben werden sollen Bitte bringen Sie diese alten Produkte und Batterien zur Behandl...

Page 12: ...F567486 FS0311 2 Printed in Malaysia Address GDD GmbH Am Goldenen Feld 18 D 95326 Kulmbach ...

Reviews: