7 Test Mode
7.1.
Power supply check mode (OVD checking)
In this mode, an abnormal power supply can be checked. Use this mode, when one or more of the following symptom occur.
(The test mode works only on the front heaters.)
Symptom:
• It takes an excessively long time to boil water. (The indicators on the operation panel are normal.)
• The pot/pan intermittently stops heating up. (The indicators on the operation panel are normal.)
• The indicators on the operation panel disappear momentarily, or display intermittently. (Heating power starts/stops simultane-
ously with the blinking indicators.)
Note:
• If "C01" is displayed in this mode, the unit itself is not malfunctioning. This indicates that the power being supplied to it is abnor-
mal, either due to an incorrect supply voltage or a disturbance in the waveform, caused by electrical noise or for other reasons.
• OVD (Over Voltage Defense,) is a damping function that is activated to temporarily stop operations in order to prevent the inner
circuit of the IH cooktop from overheating.
Remedy:
• Ascertain the source of the power supply noise and remove it. (Refer to "Noise Incidents" - KAD0507001BE.)
1. Check if the electrical noise is being caused by other equipment in the house.
2. If the noise is a coming from an outside source, approach your power company for assistance.
Operating procedures
Operation
Indicators on the operation panel
How to operate
(Each button operation has a buzzer sound.)
1.Turn the main power switch on.
2.Within 3 seconds, simultaneously press heating
Down
button of the left
front IH heater and the
Down
button of the left rear IH heater.
3.Press the left rear IH heater
(Off/On)
button.
4.Press the
Child safety lock
button for 3 seconds.
5."C" appears in the display window.
①
②
④
⑤
Summary of Contents for KY-B64BGBXD
Page 2: ...2 1 Safety Precautions ...
Page 6: ...6 3 3 Location of Controls and Components 3 3 1 Functional Assignments of Boards ...
Page 7: ...7 4 Location of Controls and Components ...
Page 8: ...8 ...
Page 9: ...9 5 Installation Instructions ...
Page 10: ...10 ...
Page 11: ...11 ...
Page 12: ...12 ...
Page 13: ...13 ...
Page 14: ...14 ...
Page 15: ...15 ...
Page 16: ...16 ...
Page 17: ...17 ...
Page 18: ...18 ...
Page 19: ...19 ...
Page 20: ...20 ...
Page 21: ...21 ...
Page 22: ...22 ...
Page 42: ...42 10 3 Spacer A 1 Remove the Spacer A ...
Page 46: ...46 3 Unplug the thermistor lead wire connector CN9 4 Remove the rear IH coil ...
Page 49: ...49 10 4 4 L1 springs 1 Remove the L1 springs 13 pcs KY B84BX B84BG KY B64BX B64BG ...
Page 59: ...59 11 Maintenance ...
Page 61: ...61 12 2 Repacking method KY B84BX B84BG BXD ...
Page 62: ...62 KY B64BX B64BG BXD ...
Page 63: ...63 12 3 Packing dimension KY B84BX B84BG BXD KY B64BX B64BG BXD ...
Page 64: ...64 13 Schematic Diagram 13 1 Wiring connection ...
Page 65: ...65 13 2 Electric circuit KY B84BX B64BX BXD ...
Page 66: ...66 KY B84BG B64BG BXD ...
Page 67: ...67 13 3 Wiring treatment ...
Page 68: ...68 14 Exploded View and Replacement Parts List 14 1 Exploded View KY B84BX BXD KY B84BG BXD ...
Page 73: ...73 14 4 Exploded View KY B64BX BXD KY B64BG BXD ...