background image

2. CONNECTION

2.1. Connecting the Handset/Telephone Line Cord

After connection, lift the handset to check for a dial tone.

4

Summary of Contents for KX-TS105B

Page 1: ...ORDER NO KM40212005C1 J01 Telephone Equipment KX TS105B Integrated Telephone System Black Version for U S A SPECIFICATIONS 1 ...

Page 2: ...2003 Panasonic Communications Co Ltd All rights reserved Unauthorized copying and distribution is a violation of law 2 ...

Page 3: ...1 LOCATION OF CONTROLS 3 ...

Page 4: ...2 CONNECTION 2 1 Connecting the Handset Telephone Line Cord After connection lift the handset to check for a dial tone 4 ...

Page 5: ...ce If you connect a communication device computer modem fax answering machine etc to the telephone line you can connect it through this unit using the DATA jack After connecting the handset and telephone line cord connect the communication device telephone line cord to the DATA jack 5 ...

Page 6: ...ory etc or the communication device may not operate properly 3 SETTINGS 3 1 Dialing Mode You can select the dialing mode by programming If you have touch tone service set to Tone If rotary or pulse service is used set to Pulse Your phone comes from the factory set to Tone Make sure that a call is not put on hold 6 ...

Page 7: ...GH 4 SPECIAL FEATURES 4 1 FLASH Button 4 2 Selecting the Flash Time The flash time depends on your telephone exchange or host PBX You can select the following flash times 80 90 100 110 200 250 300 400 600 700 ms milliseconds Your phone comes from the factory set to 600 ms Make sure that a call is not put on hold 7 ...

Page 8: ... your PBX installer for the correct setting 4 3 PIN Code A 4 digit PIN Code Personal Identification Number prevents unauthorized persons from using your unit The PIN Code is required for the dial lock and call restriction to be set or canceled The factory preset PIN code is 1111 Make sure that a call is not put on hold 8 ...

Page 9: ...ton Once you locked the dialing buttons even emergency numbers cannot be dialed Only incoming calls are accepted until the dial lock is canceled Before using this feature we recommend storing an emergency number in the memory of the EMERGENCY button Even if the dialing buttons are locked the number stored in the button can be dialed 9 ...

Page 10: ...mbers but plan to use the dial lock any number programmed into the EMERGENCY button can be accessed 4 4 1 To Set the Dial Lock 4 4 2 To Cancel the Dial Lock Follow steps 1 through 3 above again 4 4 3 To Release the Establishment of Dial Lock 10 ...

Page 11: ...After this procedure you will be able to establish a new password How to release the establishment of dial lock 11 ...

Page 12: ... the unit from dialing phone numbers beginning with specified digit s 1 digit or 2 digits Phone numbers with the restricted leading digits cannot be dialed out 4 5 1 To Set the Call Restriction Make sure that a call is not put on hold 12 ...

Page 13: ...nformation 5 REPLACEMENT PARTS LIST Ref No Part No Part Name Description Pcs Set Remarks A1 PQJA10075Z CORD TELEPHONE 1 A2 PQJA212V CORD HANDSET 1 A3 PQJXC0301Z HANDSET 1 A4 PQKL10038Y3 STAND WALL MOUNT 1 A5 PQQW12497Z QUICK GUIDE for Spanish 1 A6 PQQW12576Z LEAFLET 1 A7 PQQX13158Y INSTRUCTION BOOK 1 13 ...

Page 14: ...line from the loop simulator 2 This schematic diagram may be modified at any time with the development of new technology Important Safety Notice Components identified by mark have special characteristics important for safety When replacing any of these components use only the manufacturer s specified parts 6 1 Memo 7 SCHEMATIC DIAGRAM H M KXTS105B 14 ...

Page 15: ...Signal The voltage during ON Hook is indicated shows the voltage during OFF Hook KX TS105B SCHEMATIC DIAGRAM Battery Low 3 8V 3 9V 5 7V 4 2V 5 8V 4 5V 6 3V 3 7V 3 7V 6 3V R115 0 R185 0 390K 100K R100 180 VOUT VCC 3 R315 0 1 4 5 6 7 9 11 13 14 17 21 24 25 26 28 29 10 18 19 20 27 30 31 32 33 IC201 IC1 IC304 IC302 IC303 ...

Page 16: ...DTMF Hold Music Beep 5 8V 3 7V 3 7V 1 4 5 6 7 9 11 13 14 17 21 24 25 26 28 29 10 18 19 20 27 30 31 32 33 IC651 IC601 IC801 IC903 ...

Page 17: ...Signal The voltage during ON Hook is indicated shows the voltage during OFF Hook KX TS105B SCHEMATIC DIAGRAM Battery Low 3 8V 3 9V 5 7V 4 2V 5 8V 4 5V 6 3V 3 7V 3 7V 6 3V R115 0 R185 0 390K 100K R100 180 VOUT VCC 3 R315 0 1 4 5 6 7 9 11 13 14 17 21 24 25 26 28 29 10 18 19 20 27 30 31 32 33 IC201 IC1 IC304 IC302 IC303 ...